RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.
Circumstances for
Received Message
Mode code command
with mode code 10011
and T/ bit equals 1
Broadcast address RT31
(broadcast not allowed)
Invalid command word.
——— OR ———
T/ bit equals 0 and
UMCINV bit in Config.
Register 1 equals 1 ***
——— AND ———
UMCINV bit in Config.
Register 1 equals 0.
The Illegalization Table
bit equals 0 *
——— AND ———
UMCINV bit in Config.
Register 1 equals 0.
The Illegalization Table
bit equals 1 **
Mode code command
word is followed by a
contiguous data word
If broadcast, set the
BCR status bit.
* Command is illegal but terminal is not using “illegal command detection” (in form response).
** Command is illegal and terminal is using “illegal command detection”
*** Undefined mode command rendered invalid by UMCINV option bit. Command’s bit in Illegalization Table is “don’t care”.
MC19 EXCEPTIONS:
T/ bit equals 0
T/ bit equals 0
R
BIT WORD
TRANSMIT
R
R
(MC19)
R
automatically copied to the
assigned index or ping-pong buffer
(or to Descriptor Word 4 for SMCP
Simplified Mode Cmd Processing)
Terminal Response
to Received Command
Default response: Reset
Message Error (ME) and
BCR status bits. then
transmit Status Word
followed by data word from
either BIT Word Register or
Alternate BIT Word Register,
depending on Configuration
Reg. 2 option bit ALTBITW.
Transmitted data word is
No Status Word transmit.
Set the Message Error
(ME) and BCR status bits.
No terminal response,
the message is ignored.
No Status Word change.
(mode code is undefined
when T/ bit equals 0)
Respond “In form”: Reset
Message Error (ME) status.
If not broadcast, transmit
Status Word. If broadcast,
set the BCR status bit and
suppress status response.
Set Message Error (ME)
status. If not broadcast,
transmit Status Word.
If broadcast, also set
Status Word BCR bit and
suppress Status response.
No Status Word transmit.
Set the Message Error
(ME) status bit.
R
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL
SUMMARY OF MESSAGE RESPONSES
HOLT INTEGRATED CIRCUITS
HI-6120, HI-6121
99
Bits Updated
in Descriptor
Control Word
DBAC bit reset.
BCAST bit reset.
DPB bit toggles.
DBAC bit set.
BCAST bit set.
DPB bit toggles.
No change.
DBAC bit set.
BCAST bit updated.
DPB bit toggles.
DBAC bit set.
BCAST bit updated.
DPB bit toggles.
DBAC bit set.
BCAST bit updated.
DPB bit toggles.
Bits Updated
in Data Buffer
Msg Info Word
Normal CS update:
BUSID bit reset.
MERR bit reset.
ILCMD bit reset.
RTRT bit reset.
(All error bits reset.)
MERR bit set.
BUSID bit updated.
ILCMD bit reset.
RTRT bit reset.
(Other error bits reset.)
No Message Info
Word is written
Normal CS update:
BUSID bit updated.
MERR bit reset.
ILCMD bit reset.
RTRT bit reset.
(All error bits reset.)
ILCMD bit set.
MERR bit set.
BUSID bit updated.
RTRT bit reset.
(Other error bits reset.)
MERR bit set.
WCTERR bit set.
BUSID bit updated.
ILCMD bit reset.
RTRT bit reset.
(Other error bits reset.)
Interrupt
Options
ILCMD
MERR
MERR
None
IWA
IWA
IWA
IWA
IWA
IBR
IBR
IBR
IBR

Related parts for HI-6121PQMF