WM8580AGEFTRV WOLFSON [Wolfson Microelectronics plc], WM8580AGEFTRV Datasheet - Page 86

no-image

WM8580AGEFTRV

Manufacturer Part Number
WM8580AGEFTRV
Description
Multichannel CODEC with S/PDIF Transceiver
Manufacturer
WOLFSON [Wolfson Microelectronics plc]
Datasheet
WM8580
w
REGISTER
ADDRESS
GPO1
GPO2
R38
R39
26h
27h
BIT
3:0
7:4
3:0
7:4
8
8
ALWAYSVALID
GPO1OP[3:0]
GPO2OP[3:0]
GPO3OP[3:0]
GPO4OP[3:0]
FILLMODE
LABEL
DEFAULT
0000
0001
0010
0011
0
0
0000 = INT_N
0001 = V
0010 = U
0011 = C
0100 = P
0101 = SFRM_CLK
0110 = 192BLK
0111 = UNLOCK
1000 = CSUD
1001 = Invalid
1010 = ZFLAG
1011 = NON_AUDIO
1100 = CPY_N
1101 = DEEMP
1110 = Set GPO as S/PDIF input (standard CMOS input buffer).
Only applicable for GPO3/4/5.
1111 = Set GPO as S/PDIF input (‘comparator’ input for AC
coupled consumer S/PDIF signals). Only applicable for GPO3/4/5
Fill Mode Overwrite Configuration
Determines S/PDIF receiver action when TRANS_ERR or
INVALID flag is masked and error condition sets the flag:
0000 = INT_N
0001 = V
0010 = U
0011 = C
0100 = P
0101 = SFRM_CLK
0110 = 192BLK
0111 = UNLOCK
1000 = CSUD
1001 = Invalid
1010 = ZFLAG
1011 = NON_AUDIO
1100 = CPY_N
1101 = DEEMP
1110 = Set GPO as S/PDIF input (standard CMOS input buffer).
Only applicable for GPO3/4/5.
1111 = Set GPO as S/PDIF input (‘comparator’ input for AC
coupled consumer S/PDIF signals). Only applicable for GPO3/4/5
Automatic Error Handling Configuration for INVALID Flag
0 = INVALID flag automatic error handling enabled.
1 = INVALID flag automatic error handling disabled.
0 = Data from S/PDIF receiver is overwritten with last valid
data sample when flag is set.
1 = Data from S/PDIF receiver is overwritten as all zeros
when flag is set.
DESCRIPTION
PD Rev 4.3 August 2007
Production Data
86