PEB2085 SIEMENS [Siemens Semiconductor Group], PEB2085 Datasheet - Page 281

no-image

PEB2085

Manufacturer Part Number
PEB2085
Description
ISDN SubscribernAccess Controller
Manufacturer
SIEMENS [Siemens Semiconductor Group]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2085-P
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Part Number:
PEB2085N
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEB2085N
Manufacturer:
ALLEGRO
Quantity:
5 510
Part Number:
PEB2085N
Manufacturer:
LNFINEON
Quantity:
20 000
Part Number:
PEB2085N V2.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB2085NV1.1
Manufacturer:
PHI
Quantity:
399
Part Number:
PEB2085NV1.1
Manufacturer:
SIE
Quantity:
1 000
Part Number:
PEB2085NV1.1
Manufacturer:
SIE
Quantity:
20 000
Part Number:
PEB2085NV2.3
Manufacturer:
SIEMENS
Quantity:
5 967
Part Number:
PEB2085NV2.3
Manufacturer:
SIE
Quantity:
1 000
Part Number:
PEB2085NV2.3
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Part Number:
PEB2085P
Quantity:
41
Part Number:
PEB2085P
Manufacturer:
SIEMENS
Quantity:
1 000
6.5
6.5.1
ActL1_SBC ()
Initiates layer-1 activation. The appropriate CI code (activate request) is written to the CI
channel if the layer 1 is not already activated. ActL1_SBC then returns with ACK_DONE. The
subsequent status changes of the SBC will cause CI channel status change (CISQ) interrupts
and these will be evaluated in the layer-1 interrupt service routine IntL1_SBC.
If the layer 1 is already activated nothing is carried out but ActL1_SBC calls
DECODE_L1_STATUS to report the activated state.
DeaL1_SBC ()
Initiates layer 1 deactivation. The appropriate CI code is written to the CI channel if the layer 1
is not already deactivated. The subsequent layer 1 status changes cause CI channel status
change (CISQ) interrupts and these will be evaluated in the layer 1 interrupt service routine
IntL1_SBC.
If the layer 1 is already deactivated nothing is carried out but DeaL1_SBC calls
DECODE_L1_STATUS to report the deactivated state.
ArL1_SBC ()
Activates a local loop in the SBC. The appropriate CI code (activate request loop) is written to
the SBC. ArL1_SBC returns with ACK_DONE. The subsequent status changes of the SBC will
generate CISQ interrupts and these will be evaluated and reported in the layer-1 interrupt
service routine IntL1_SBC.
EnaClk_SBC ()
EnaClk_SBC enables clocking in TE configurations when the layer 1 is in power down state.
If first tests if clocks are actually there. If there are clocks the function returns with FALSE. If
there are no clocks (power down state) the power-up procedure is implemented. The SPU bit
in register SPCR is set. The TIM code is written to the CI channel. EnaClk_SBC waits until the
power up state (PU) is indicated before the SPU bit is reset to 0. The routine then returns with
TRUE.
InitL1_SBC ()
Initializes and resets the layer-1 controller (ResL1_SBC). Timing mode 0 is set and the TIC
bus address is also programmed.
Semiconductor Group
LLC Routine Reference
ISAC
®
-S Layer-1 Functions: The SBC Part
281
Low Level Controller