PEB2085 SIEMENS [Siemens Semiconductor Group], PEB2085 Datasheet - Page 208

no-image

PEB2085

Manufacturer Part Number
PEB2085
Description
ISDN SubscribernAccess Controller
Manufacturer
SIEMENS [Siemens Semiconductor Group]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2085-P
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Part Number:
PEB2085N
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEB2085N
Manufacturer:
ALLEGRO
Quantity:
5 510
Part Number:
PEB2085N
Manufacturer:
LNFINEON
Quantity:
20 000
Part Number:
PEB2085N V2.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB2085NV1.1
Manufacturer:
PHI
Quantity:
399
Part Number:
PEB2085NV1.1
Manufacturer:
SIE
Quantity:
1 000
Part Number:
PEB2085NV1.1
Manufacturer:
SIE
Quantity:
20 000
Part Number:
PEB2085NV2.3
Manufacturer:
SIEMENS
Quantity:
5 967
Part Number:
PEB2085NV2.3
Manufacturer:
SIE
Quantity:
1 000
Part Number:
PEB2085NV2.3
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Part Number:
PEB2085P
Quantity:
41
Part Number:
PEB2085P
Manufacturer:
SIEMENS
Quantity:
1 000
The internal timer procedure will be started in auto-mode:
VALUE Determines the Time Period T1:
Semiconductor Group
The timer procedure will be stopped when
Note: The maximum value of CNT can be 6. If CNT is set to 7, the number of retries
* External Timer Mode (TMD = 0)
CNT together with VALUE determine the time period T2 after which a TIN interrupt
will be generated:
CNT 2.048 s + T1
with T1 = (VALUE + 1) 0.064 s,
in the normal case, and
T2 = 16348 CNT DCL + T1
with T1 = 512 (VALUE + 1) DCL
when TLP = 1 (test loop activated, SPCR register).
DCL denotes the period of the DCL clock.
The timer can be started by setting the STI-bit in CMDR and will be stopped when a
TIN interrupt is generated or the TIMR register is written.
Note: If CNT is set to 7, a TIN interrupt is indefinitely generated after every
T1 = (VALUE + 1) 0.064 s (SPCR:TLP = 0, normal mode)
T1 = 512 (VALUE + 1) DCL (SPCR:TLP = 1, test mode).
– after start of an I-frame transmission
or
– after an "RNR" S-frame has been received.
After the last retry, a timer interrupt (TIN-bit in ISTA) is generated.
– a TIN interrupt is generated. The time between the start of an I-frame
– or the TIMR is written
– or a positive or negative acknowledgement has been received.
transmission or reception of an "RNR" S-frame and the generation of a TIN
interrupt is equal to: (CNT+1) T1.
is unlimited.
expiration of T1.