MPC2F35E2 MEGAWIN [Megawin Technology Co., Ltd], MPC2F35E2 Datasheet - Page 29

no-image

MPC2F35E2

Manufacturer Part Number
MPC2F35E2
Description
Low-speed USB micro-controller
Manufacturer
MEGAWIN [Megawin Technology Co., Ltd]
Datasheet
RXSTAT: Endpoint Receive Status Register (Endpoint-Indexed)
Read/Write
Default: 0000_0XXX
Number
MEGAWIN
Bit
7
6
5
4
3
2
1
0
Mnemonic
RXSETUP
RXSOVW
EDOVW
STOVW
RXSEQ
Bit
-
-
-
Receive Endpoint Sequence Bit (read, conditional write):
The bit will be toggled on completion of an ACK handshake in response to
an OUT token. This bit can be written by firmware if the RXOVW bit is set
when written along with the new RXSEQ value.
Received Setup Transaction:
This bit is set by hardware when a valid SETUP transaction has been
received. Clear this bit upon detection of a SETUP transaction or the
firmware ready to handle the data/status stage of control transfer.
Start Overwrite Flag (read-only):
Set by hardware upon receipt of a SETUP token for any control endpoint to
indicate that the receive FIFO is being overwritten with new SETUP data.
This bit is used only for control endpoints.
End Overwrite Flag:
This flag is set by hardware during the handshake phase of a SETUP
stage. This bit is cleared by firmware to read FIFO data. This bit is only
used for control endpoints.
Receive Data Sequence Overwrite Bit:
Write ‘1’ to this bit to allow the value of the RXSEQ bit to be overwritten.
Writing a ‘0’ to this bit, it has no effect on RXSEQ. This bit always returns to
‘0’ when read.
Reserved:
Write zero to this bit.
Reserved:
Write zero to this bit.
Reserved:
Write zero to this bit.
MPC2F35_USB Data Sheet
Function
Address: 22H
System Reset or USB Reset
29

Related parts for MPC2F35E2