2032-A0085JX-27J ALLEN-BRADLEY [Allen-Bradley], 2032-A0085JX-27J Datasheet - Page 7

no-image

2032-A0085JX-27J

Manufacturer Part Number
2032-A0085JX-27J
Description
ElectroGuard
Manufacturer
ALLEN-BRADLEY [Allen-Bradley]
Datasheet
Status Communication to a remote PLC (Should be ordered with Safety Isolation System)
This option provides Remote I/O via “Flex” modules. Communication can be via:
• The DeviceNet communication platform, or
• The Remote I/O communication platform.
Note: The status communication option allows a remote PLC to receive status signals
from the ElectroGuard Safety Isolation System. The ElectroGuard does not accept input
signals through these communication platforms.
Status communication capabilities:
• Overall system status,
• Status of each Remote Lockout Station,
• Status of the Pneumatic Isolation Module (if used),
• Status of other optional Safety Input devices.
Note: Each communication module provides sixteen (16) data points. In determining which Catalogue Number String to specify from the table below,
please keep the following in mind:
• Overall system status information requires one (1) data point.
• The Pneumatic Isolation Module (if used) requires one (1) data point.
• Each Remote Lockout Station used in the application requires one (1) data point.
• Each optional Rockwell Automation Safety Input device (i.e. Safety Mat, Light Curtain, E-Stop Station, Proximity Switch, Photo Switch)
To order the Status Communication to a remote PLC option, add one of the following Catalogue Strings to the Safety
Isolation System Catalogue Number:
"
!
Cover Mounted Metering (Must be ordered with Safety Isolation System):
Cover mounted ammeters and/or voltmeters are available as factory installed options in order to provide visual indication of line side system
current and/or voltage.
To order metering, add one or more of the following Catalogue Strings to the Safety Isolation System Catalogue
Number:
Remote I/O
DeviceNet
Single-phase Ammeter
Three-phase Ammeter
Single-phase Voltmeter
Three-phase Voltmeter
Only available on units from 110A through 1200A.
e.g. Catalogue Number 2031-A0085JB becomes Catalogue Number 2031-A0085JB-1COM to indicate an 85A Safety Isolation System that includes 16 points of
Maximum available for units from 23A through 85A.
e.g. Catalogue Number 2031-A0085JB becomes Catalogue Number 2031-A0085JB-1AM to indicate an 85A Safety Isolation System that includes a cover mounted
requires one (1) data point.
Remote I/O for status communication to a remote PLC.
single-phase Ammeter.
Type of Metering Required
Communication Platform
Catalogue Number String
-1AM
-3AM
-1VM
-3VM
Number of I/O points
16 points
32 points
48 points
64 points
16 points
32 points
48 points
64 points
Optional Features (continued)
Catalogue Number String
Safety Isolation System
ElectroGuard
-3DNET"
-4DNET!
-3COM"
-4COM!
-1DNET
-2DNET
-1COM
-2COM
12-17