MSR122E ALLEN-BRADLEY [Allen-Bradley], MSR122E Datasheet

no-image

MSR122E

Manufacturer Part Number
MSR122E
Description
Expansion Units
Manufacturer
ALLEN-BRADLEY [Allen-Bradley]
Datasheet
Safety Relays
Expansion Units
Minotaur MSR122E
Description
The MSR122E is designed to be an expansion relay for use with the
Minotaur safety relays. The MSR122E is typically used in safety
system applications where additional outputs switching connections
are needed to help shut down a manufacturing process, properly and
safely.
The MSR122E can be connected as a single channel (1 N.C.) or dual
channel (2 N.C.) input configuration.
The outputs include 6 normally open safety rated outputs used to
shut down the manufacturing system and 1 normally closed auxiliary
output to indicate the status of the MSR122E. One additional
normally closed output is available to allow the host relay to monitor
the status of the MSR122E. The safety, auxiliary and monitoring
outputs have independent and redundant internal contacts to help
ensure the safety function.
Features
• Safety category according to wiring
• 6 Safety contacts
• 1 Auxiliary contact
• 1 Monitoring contact
Contact Current Limit Curve
4-58
250
200
150
100
50
0
0
10
Ambient temperature/°C
20
30
40
ACV
24V
50
60
Specifications
Standards
Category
Approvals
Power Supply
Power Consumption
Safety Inputs
Input Simultaneity
Maximum Input Resistance
Outputs
Output Utilization per IEC
60947-4-1 (Resistive)
per IEC 60947-5-1 N.O.
(Inductive) N.C.
Thermal Current (non switching) See limit curve
Fuses Output (external)
Min. Switched Current/Voltage
Contact Material
Response Time
Indication LEDs
Impulse Withstand Voltage
Pollution Degree
Operating Temperature
Enclosure Protection
Terminal Protection
Conductor Size
Torque Settings—term. screws
Mounting
Weight
Electrical Life (w/Surge Supp.)
Mechanical Life
Vibration
Shock
N.O.
N.C.
250V AC/5A/1250VA cos =0.35
See Output Ratings on page 1-29 for details. Consult factory for ratings not
250V AC/5A/1250VA cos =0.6
Output Utilization
shown.
250V AC/10A/2500VA cos =1
250V AC/5A/1250VA cos =1
10V DC/0.01A/0.1W
24V DC/2A/48W
EN 954-1, ISO 13849-1, IEC/EN
60204-1, IEC 60947-5-1, ANSI
B11.19, AS4024.1
Cat. 3 per EN 954-1 (ISO13849-1)
C-Tick, CE marked for all
applicable directives, cULus and BG
24V AC/DC, 115V AC or 230V AC
0.8 to 1.1 x rated voltage, 50/60 Hz
(0.85 to 1.1 x 24V DC)
3W
1 N.C. or 2 N.C.
Infinite
160 ohms
6 N.O. Safety
1 N.C. Auxiliary
1 N.C. Monitoring
AC-1: 10A/250V AC
DC-1: 10A/24V DC
A300, AC-15
N300, DC-13
Max 10A in one current path
6A Slow Blow or 10A Quick Blow
10mA/10V
AgSnO
30ms
Green = CH1 Closed
Green = CH2 Closed
2500V
2
-5°C to +50°C (+23°F to 122°F)
IP40 (NEMA 1)
IP20
0.2–4mm
0.4Nm (3.54 lb in)
35mm DIN rail
550g (1.21lbs)
300,000 operations
700,000 operations
350,000 operations
500,000 operations
1,000,000 operations
2,000,000 operations
5,000,000 operations
10-55 Hz, 0.35mm
10g, 16ms, 100 shocks
10A/24V DC @ 6 ops/min
5A/250V AC, 5A/125V AC
2A/250V AC, 2A/125V AC
4A/24V DC
2
+ 0.5 Au
2
(24-12AWG)