Lock Register
Persistent Protection Bits
As shipped from the factory, all devices default to the persistent mode when power is applied, and
all sectors are unprotected, unless otherwise chosen through the DYB ordering option (see
dering
protection method to use. Programming (setting to 0) any one of the following two one-time pro-
grammable, non-volatile bits locks the part permanently in that mode:
T Lock Register Persistent Protection Mode Lock Bit (DQ1)
T Lock Register Password Protection Mode Lock Bit (DQ2)
For programming lock register bits see
Notes
1.
2.
3.
4.
After selecting a sector protection method, each sector can operate in any of the following three
states:
1.
2.
3.
These states are controlled by the bit types described in Sections
The Persistent Protection Bits are unique and nonvolatile for each sector and have the same en-
durances as the Flash memory. Preprogramming and verification prior to erasure are handled by
the device, and therefore do not require system monitoring.
S29PL256N
Device
If the password mode is chosen, the password must be programmed before setting the cor-
responding lock register bit.
After the Lock Register Bits Command Set Entry command sequence is written, reads and
writes for Bank A are disabled, while reads from other banks are allowed until exiting this
mode.
If both lock bits are selected to be programmed (to zeros) at the same time, the operation
aborts.
Once the Password Mode Lock Bit is programmed, the Persistent Mode Lock Bit is perma-
nently disabled, and no changes to the protection scheme are allowed. Similarly, if the
Persistent Mode Lock Bit is programmed, the Password Mode is permanently disabled.
Constantly locked. The selected sectors are protected and cannot be reprogrammed unless
PPB lock bit is cleared via a password, hardware reset, or power cycle.
Dynamically locked. The selected sectors are protected and can be altered via software
commands.
Unlocked. The sectors are unprotected and can be erased and/or programmed.
Information). The device programmer or host system must then choose which sector
Undefined
DQ15 – 05
P r e l i m i n a r y
DYB Lock Boot Bit
0 = sectors 
power up 
protected
1 = sectors
power up 
unprotected
S29PL-N MirrorBit™ Flash Family
DQ4
Table 10.1 Lock Register
Table
PPB One-Time 
Programmable Bit
0 = All PPB erase 
command disabled
1 = All PPB Erase 
command enabled
15.2.
DQ3
Password
Protection
Mode Lock Bit
DQ2
10.2
Persistent
Protection
Mode Lock Bit
– 10.6.
DQ1
Secured
Silicon Sector 
Protection Bit
DQ0
Or-