s5u1c17001c Epson Electronics America, Inc., s5u1c17001c Datasheet - Page 423

no-image

s5u1c17001c

Manufacturer Part Number
s5u1c17001c
Description
Cmos 16-bit Application Specific Controller
Manufacturer
Epson Electronics America, Inc.
Datasheet
Limitations
S5U1C17001C MANUAL
(C COMPILER PACKAGE FOR S1C17 FAMILY) (Ver. 1.1)
Changing display format
Rewriting variable values
The format in which to display variable values can be selected from the following:
Hex:
Decimal:
Binary:
Octal:
Natural:
Select a variable whose display format you wish to change by clicking on its line in the window.
Next, choose the desired display format from the [Format] submenu of the [Variable] menu.
Otherwise, you can choose a display format from the popup menu shown below that appears by right-clicking.
Variable values can be changed directly in the window.
Select a variable whose content you wish to change by clicking it in the window.
Next, choose [Edit] from the [Variable] menu or the popup menu that appears by right-clicking. The variable
value will be highlighted with a blue background while a text cursor appears behind the value, indicating that
the variable is in edit mode. You also can enter edit mode by double-clicking a variable value.
Enter a new value in decimal or hexadecimal to replace the existing value or change the necessary digits of the
existing value. You can use the arrow, backspace, and delete keys.
Entering a value exceeding the data size of the variable only applies the low-order effective bits and ignores the
bits outside the valid range.
• The local variable values displayed in the [Local Variables] window are not updated even when using a
• The value of the variable, which is allocated to a register, may not be displayed properly due to the
command to correct the contents of these values. Variable values are only updated when changed during
program execution.
optimization by the C compiler.
Hexadecimal
Signed decimal
Binary
Octal
Common representation for the data type (e.g. decimal for int type values, hexadecimal for
pointers) (default)
Selected variable
Edit mode