s5u1c17001c Epson Electronics America, Inc., s5u1c17001c Datasheet - Page 256

no-image

s5u1c17001c

Manufacturer Part Number
s5u1c17001c
Description
Cmos 16-bit Application Specific Controller
Manufacturer
Epson Electronics America, Inc.
Datasheet
5 GNU17 IDE
The default setting shows the command to set the debugger in ICD Mini mode. If simulator mode is used, rewrite
the command directly in this page or replace the command using the [Create a simple startup command] dialog box
shown below that appears by clicking the [Create commands from template] button.
Command file for simulator mode
This command file is executed when the debugger starts up making the following initial settings:
1. Import debug information and parameter map information.
2. Set connect mode.
3. Set TTBR. (only in simulator mode)
4. Load the object file to be debugged.
5. Set the PC (program counter) to the boot address.
These initial settings enable the debugger to execute a program from the boot address immediately after launching.
If other commands must be executed, enter them from the keyboard to add to the command list.
For detailed information on debugger commands, refer to Chapter 10, "Debugger".
The debugger startup commands in the command file may be edited using an editor.
Note, however, that the contents of the command file may not be displayed on the [GNU17 GDB Commands] page
if the command file is being opened in an external editor when the [Properties] dialog box is opened. In this case,
open the [Properties] dialog box after closing the command file in the external editor.
[Create a simple startup command]
[Debugger:]
[Boot vector address] (effective only in simulator mode)
5-150
# Command file generated by Gnu17 Plug-in for Eclipse
# load debugging information in program
file sample.elf
# set the memory configuration map file to the debugger
c17 rpf sample_gnu17IDE.par
# set ttbr for simulator
c17 ttbr 0x008000
# connect to the debugger with specified mode and port
# target [icd usb | sim]
target sim
# load program to memory
load sample.elf
# reset
c17 rst
Select the debugger (connect mode) to connect to.
ICD Mini
Simulator To debug with a PC only.
Enter the boot vector address in hexadecimal notation (omit 0x) in the text box when creating a command file
for simulator mode. The address may be specified in 256-byte increments. The IDE generates a command file
for simulator mode that includes a command for setting this value to the boot vector address. The value ap-
peared here by default is the address that was specified when the project was created.
When using an ICD to debug.
EPSON
... Loads debug information.
... Loads a parameter file.
... Sets TTBR.
... Sets connect mode.
... Loads elf object file.
... Reset
(C COMPILER PACKAGE FOR S1C17 FAMILY) (Ver. 1.1)
S5U1C17001C MANUAL