Electromagnetic Interference (EMI)
Equipment incorporating gigabit transceivers is typically 
subject  to  regulation  by  the  FCC  in  the  United  States, 
CENELEC EN55022 (CISPR 22) in Europe and VCCI in Japan. 
The  AFCT-57D5ANPZ’s  compliance  to  these  standards  is 
detailed in Table 1. The metal housing and shielded design 
of the AFCT-57D5ANPZ minimizes the EMI challenge facing 
the equipment designer.
Table 1. Regulatory Compliance
Feature
Electrostatic Discharge (ESD) 
to the Electrical Pins 
Electrostatic Discharge (ESD) 
to the Duplex LC Receptacle 
Electrostatic Discharge (ESD) 
to the Optical Connector 
Electromagnetic Interference 
(EMI) 
Immunity 
Laser Eye Safety and 
Equipment Type Testing 
Component Recognition 
RoHS Compliance 
5
Product Safety
Rheinland
TUV
¬
APPROVED
GEPRUFT
BAUART
TYPE
¬
Test Method
MIL-STD-883C  
Method 3015.4
Variation of IEC 61000-4-2 
GR1089 
Variation of IEC 801-2 
FCC Class B 
CENELEC EN55022 Class B 
(CISPR 22A) 
VCCI Class 1 
Variation of IEC 61000-4-3 
US FDA CDRH AEL Class 1 
US21 CFR, Subchapter J per 
Paragraphs 1002.10 
  and 1002.12 
(IEC) EN60825-1: 1994 + A11 + A2 
(IEC) EN60825-2: 1994 + A1 
(IEC) EN60950: 1992 + A1 + A2 + 
  A3 + A4 + A11
Underwriters Laboratories and 
Canadian Standards Association 
Joint Component Recognition 
for Information Technology 
Equipment including Electrical 
Business Equipment
EMI Immunity (Susceptibility)
Due to its shielded design, the EMI immunity of the AFCT-
57D5ANPZ exceeds typical industry standards. 
Flammability
The AFCT-57D5ANPZ optical transceiver is made of metal 
and high strength, heat resistant, chemical resistant and 
UL 94V-0 flame retardant plastic.
Performance
Class 1  (> 2000 Volts) 
Typically, no damage occurs with 25 kV when 
the duplex LC connector receptacle is 
contacted by a Human Body Model probe. 
10 contacts of 8 kV on the electrical faceplate 
with device inserted into a panel. 
Air discharge of 15 kV (min.) contact to 
connector without damage. 
System margins are dependent on customer 
board and chassis design. 
Typically shows no measurable effect from a  
10 V/m field swept from 10 MHz to 1 GHz.
CDRH certification TBD 
TUV file TBD 
UL file TBD 
Less than 1000 ppm of cadmium, lead, mercury, 
hexavalent chromium, polybrominated biphenyls,  
and polybrominated biphenyl ethers.