Table 10. Transceiver Digital Diagnostic Monitor (Real Time Sense) Characteristics
(T
Parameter
Transceiver Internal Temperature 
Accuracy 
Transceiver Internal Supply 
Voltage Accuracy 
Transmitter Laser DC Bias Current 
Accuracy
Transmitted Average Optical 
Output Power Accuracy 
Received Average Optical Input 
Power Accuracy 
Figure 4. Transceiver timing diagrams (module installed except where noted).
C
= -10°C to 85°C, VccT, VccR = 3.3 V ±10%)
t-init: TX DISABLE NEGATED
t-fault: TX FAULT ASSERTED, TX SIGNAL NOT RECOVERED
t-init: TX DISABLE NEGATED, MODULE HOT PLUGGED
t-fault: TX DISABLE ASSERTED THEN NEGATED, TX SIGNAL NOT RECOVERED
* SFP SHALL CLEAR TX_FAULT IN
< t_init IF THE FAILURE IS TRANSIENT
TRANSMITTED SIGNAL
TRANSMITTED SIGNAL
TRANSMITTED SIGNAL
OCCURANCE OF FAULT
TRANSMITTED SIGNAL
OCCURANCE OF FAULT
V
V
CC
CC
TX_DISABLE
T,R > 2.97 V
TX_DISABLE
TX_DISABLE
T,R > 2.97 V
TX_FAULT
TX_FAULT
TX_DISABLE
TX_FAULT
TX_FAULT
INSERTION
t_init
t_reset
t_init
t_fault
Symbol
T
V
I
P
P
INT
INT
INT
T
R
t_fault
t_init*
Min.
±3.0 
±0.1 
±10 
±3.0 
±3.0 
Units
°C 
V 
% 
dB 
dB 
Notes
Temperature is measured internal to the transceiver.
Valid from =  -10°C to 85°C case temperature.
Supply voltage is measured internal to the transceiver
and can, with less accuracy, be correlated to 
voltage at the SFP Vcc pin. Valid over 3.3 V ± 10%.
I
Coupled into single-mode fiber. Valid from
100 µW to 500 µW, avg. 
Coupled from single-mode fiber. Valid from
15 µW to 500 µW, avg.
INT
t-init: TX DISABLE ASSERTED
t-off & t-on: TX DISABLE ASSERTED THEN NEGATED
t-reset: TX DISABLE ASSERTED THEN NEGATED, TX SIGNAL RECOVERED
t-loss-on & t-loss-off
* SFP SHALL CLEAR TX_FAULT IN
< t_init IF THE FAILURE IS TRANSIENT
 is better than ±10% of the nominal value.
TRANSMITTED SIGNAL
TRANSMITTED SIGNAL
TRANSMITTED SIGNAL
OCCURANCE OF FAULT
V
OPTICAL SIGNAL
CC
TX_DISABLE
TX_DISABLE
T,R > 2.97 V
TX_DISABLE
TX_FAULT
TX_FAULT
TX_FAULT
LOS
t_loss_on
t_off
t_reset
OCCURANCE
OF LOSS
t_init
t_init*
t_on
t_loss_off