afct-57d5anpz Avago Technologies, afct-57d5anpz Datasheet - Page 12
afct-57d5anpz
Manufacturer Part Number
afct-57d5anpz
Description
Digital Diagnostic Sfp Small Form Pluggable , Low Voltage 3.3 V 25km, 1310nm Dfb, 8.5/4.25/2.125 Gbd Fibre Channel Rohs Compliant Digital Diagnostic Optical Transceiver
Manufacturer
Avago Technologies
Datasheet
1.AFCT-57D5ANPZ.pdf
(18 pages)
12
Table 10. Transceiver Digital Diagnostic Monitor (Real Time Sense) Characteristics
(T
Parameter
Transceiver Internal Temperature
Accuracy
Transceiver Internal Supply
Voltage Accuracy
Transmitter Laser DC Bias Current
Accuracy
Transmitted Average Optical
Output Power Accuracy
Received Average Optical Input
Power Accuracy
Figure 4. Transceiver timing diagrams (module installed except where noted).
C
= -10°C to 85°C, VccT, VccR = 3.3 V ±10%)
t-init: TX DISABLE NEGATED
t-fault: TX FAULT ASSERTED, TX SIGNAL NOT RECOVERED
t-init: TX DISABLE NEGATED, MODULE HOT PLUGGED
t-fault: TX DISABLE ASSERTED THEN NEGATED, TX SIGNAL NOT RECOVERED
* SFP SHALL CLEAR TX_FAULT IN
< t_init IF THE FAILURE IS TRANSIENT
TRANSMITTED SIGNAL
TRANSMITTED SIGNAL
TRANSMITTED SIGNAL
OCCURANCE OF FAULT
TRANSMITTED SIGNAL
OCCURANCE OF FAULT
V
V
CC
CC
TX_DISABLE
T,R > 2.97 V
TX_DISABLE
TX_DISABLE
T,R > 2.97 V
TX_FAULT
TX_FAULT
TX_DISABLE
TX_FAULT
TX_FAULT
INSERTION
t_init
t_reset
t_init
t_fault
Symbol
T
V
I
P
P
INT
INT
INT
T
R
t_fault
t_init*
Min.
±3.0
±0.1
±10
±3.0
±3.0
Units
°C
V
%
dB
dB
Notes
Temperature is measured internal to the transceiver.
Valid from = -10°C to 85°C case temperature.
Supply voltage is measured internal to the transceiver
and can, with less accuracy, be correlated to
voltage at the SFP Vcc pin. Valid over 3.3 V ± 10%.
I
Coupled into single-mode fiber. Valid from
100 µW to 500 µW, avg.
Coupled from single-mode fiber. Valid from
15 µW to 500 µW, avg.
INT
t-init: TX DISABLE ASSERTED
t-off & t-on: TX DISABLE ASSERTED THEN NEGATED
t-reset: TX DISABLE ASSERTED THEN NEGATED, TX SIGNAL RECOVERED
t-loss-on & t-loss-off
* SFP SHALL CLEAR TX_FAULT IN
< t_init IF THE FAILURE IS TRANSIENT
is better than ±10% of the nominal value.
TRANSMITTED SIGNAL
TRANSMITTED SIGNAL
TRANSMITTED SIGNAL
OCCURANCE OF FAULT
V
OPTICAL SIGNAL
CC
TX_DISABLE
TX_DISABLE
T,R > 2.97 V
TX_DISABLE
TX_FAULT
TX_FAULT
TX_FAULT
LOS
t_loss_on
t_off
t_reset
OCCURANCE
OF LOSS
t_init
t_init*
t_on
t_loss_off