LM3S818 Luminary Micro, Inc, LM3S818 Datasheet - Page 323

no-image

LM3S818

Manufacturer Part Number
LM3S818
Description
Lm3s818 Arm Microcontroller
Manufacturer
Luminary Micro, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM3S818-EQN50-C2
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S818-EQN50-C2T
Manufacturer:
MICRON
Quantity:
1 200
Part Number:
LM3S818-EQN50-C2T
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S818-IGZ50-C2
Manufacturer:
TI
Quantity:
82
Part Number:
LM3S818-IQN50-C2
Quantity:
1 947
Company:
Part Number:
LM3S818-IQN50-C2
Quantity:
330
Part Number:
LM3S818-IQN50-C2T
Manufacturer:
Texas Instruments
Quantity:
10 000
February 6, 2007
Reset
Reset
Type
Type
Bit/Field
31:6
PWM Output Fault (PWMFAULT)
Offset 0x010
5
4
3
2
1
0
RO
RO
31
15
0
0
Register 5: PWM Output Fault (PWMFAULT), offset 0x010
This register controls the behavior of the PWM outputs in the presence of fault conditions. Both the
fault input and debug events are considered fault conditions. On a fault condition, each PWM
signal can either be passed through unmodified or driven Low. For outputs that are configured for
pass-through, the debug event handling on the corresponding PWM generator also determines if
the PWM signal continues to be generated.
Fault condition control happens before the output inverter, so PWM signals driven Low on fault are
inverted if the channel is configured for inversion (therefore, the pin is driven High on a fault
condition).
RO
RO
30
14
0
0
reserved
Fault5
Fault4
Fault3
Fault2
Fault1
Fault0
Name
RO
RO
29
13
0
0
RO
RO
28
12
0
0
Type
R/W
R/W
R/W
R/W
R/W
R/W
RO
RO
RO
27
11
0
0
reserved
RO
RO
26
10
0
0
Reset
RO
RO
25
0
9
0
0
0
0
0
0
0
0
Preliminary
RO
RO
24
0
8
0
reserved
Description
Reserved bits return an indeterminate value, and should
never be changed.
When set, the PWM5 output signal is driven Low on a fault
condition.
When set, the PWM4 output signal is driven Low on a fault
condition.
When set, the PWM3 output signal is driven Low on a fault
condition.
When set, the PWM2 output signal is driven Low on a fault
condition.
When set, the PWM1 output signal is driven Low on a fault
condition.
When set, the PWM0 output signal is driven Low on a fault
condition.
RO
RO
23
0
7
0
RO
RO
22
0
6
0
Fault5
R/W
RO
21
0
5
0
Fault4
R/W
RO
20
0
4
0
Fault3
R/W
RO
19
0
3
0
LM3S818 Data Sheet
Fault2
R/W
RO
18
0
2
0
Fault1
R/W
RO
17
0
1
0
Fault0
R/W
RO
16
0
0
0
323

Related parts for LM3S818