MAS281 Dynex, MAS281 Datasheet - Page 7

no-image

MAS281

Manufacturer Part Number
MAS281
Description
MIL-STD-1750A Microprocessor
Manufacturer
Dynex
Datasheet
after SYNCN goes low to indicate the start of a new machine
cycle and remains valid until a new SYNCN cycle is begun,
RD/WN is placed in the high impedance state during DMA and
Hold cycles.
2.2.7 MEMORY/INPUT-OUTPUT (M/IO)
transfer of the AD bus that is occurring. A high state identifies
memory transfers. A low state identifies l/O transfers. M/ION
goes valid shortly after SYNCN goes low to indicate the start of
a new machine cycle and remains valid until a new SYNCN
cycle is begun. M/ION is placed in the high impedance state
during DMA and Hold cycles and is held high during internal
(non-XIO) operations.
2.2.8 INSTRUCTION/OPERAND (IN/OP)
data on the AD bus during the data portion of a SYNCN cycle.
A high state identifies an instruction while a low state identifies
an operand. IN/OPN goes valid shortly after SYNCN goes low
to indicate the start of a new SYNCN cycle and remains valid
until a new SYNCN cycle is begun. This signal is required
during expanded memory accesses. IN/OPN is placed in the
high impedance state during DMA and Hold cycles.
Output/Hi-Z, This dual function signal indicates the type of
Output/Hi-Z. This dual function signal indicates the type of
Figure 5: Typical MAS281/MA31751 System Interface
2.2.9 ADDRESS/DATA BUS (AD00 - AD15)
bidirectional multiplexed address and data bus which serves
both as the communication path between the external system
and module as well as the communication path among the
three chips on the module. It is important to note that the AD
bus is shared between the external system and internal
module resources. To avoid bus contention during internal
operations, the AD bus must be isolated from the external
system through the use of a bus transceiver. A data direction
signal (DDN) is provided for transceiver control .
are represented in positive logic. A high level indicates a logic
1 and a low level indicates a logic 0. AD00 is the most
significant bit position whilst AD15 is the least significant bit
position. The AD bus is placed in the high impedance state
during the data portion of a read SYNCN cycle as well as
during DMA and Hold cycles.
2.2.10 READY (RDY)
sequencer, in conjunction with the internal ready signal, to
determine when the current machine cycle may be completed.
By holding RDYN high, wait states may be inserted, stretching
out the current machine cycle and allowing slower devices
sufficient time to complete their operations.
high-to-low transitions (with DSN low), a bus timeout fault will
occur and will be indicated in the appropriate bit in the fault
register. The occurrence of this fault will cause the EU state
sequencer to terminate the current machine cycle, drop
SYNCN low, and begin a new machine cycle. Also, the
presently executing macroinstruction will be aborted and
execution will branch, unless masked, to the machine error
interrupt (level 1) software routine. The DTON signal may be
used to override this feature.]
2.2.11 CONTROL DIRECTION (CD)
driving the AS, DSN, M/ION, RD/WN and IN/OPN signals.
During DMA and Hold cycles, this signal goes low to indicate
the module has relinquished control of these signals and has
placed them in the high impedance state. The DMA or Console
controller, respectively, may then drive these signals. This
signal should be used to control the transfer direction of the
control signal transceiver.
2.2.12 DATA DIRECTION (DD)
transfer on the AD bus. This signal goes high to indicate a write
transfer from the module to the external system. It also goes
high during all internal module operations. DDN goes low to
indicate a read transfer from the external system to the
module. It also goes low during DMA and Hold cycles as well
as during configuration register reads.
internally implemented XIO commands, DDN also goes high
Input/Output/Hi-Z. AD00 through AD15 comprise a
Addresses, data and commands appearing on the AD bus
This asynchronous active low input is used by the EU state
This active low output goes high to indicate the module is
This active low signal indicates the direction of data
[Note: In addition to going high during the execution of
[Note: If RDYN is held high during two consecutive TCLK
MAS281
7/55