7.7 Turn-on time
VTI Technologies Oy
Myllynkivenkuja 6
P.O. Box 27
FI-01621 Vantaa
www.vti.fi
Cross-axis sensitivity of CMR3000 family is measured in rate table over specified measurement
range during qualification. Correct mounting position of component is important during the
measurement of cross-axis sensitivity.
Turn-on time is the time when the last of one X, Y, Z axis output readings stabilizes into its final
value after measurement mode has been activated. The final value limits in turn-on time
measurements is defined to be ±1 % of the sensor’s full scale measuring range (for example for
CMR3000-D01 ±1000 dps → FS = 1000 dps). Turn-on time definition for Z-axis is presented in
Figure 17 below.
Angular rate
Figure 17. Turn-on time definition for one axis.
CMR3000
Z-axis output
Turn on time
Doc.Nr. 82112900.A.02
Time scale
Supply voltage reaches the
minimum required level
→ CMR3000 starts
CMR3000 output
inside ±1% FS
limits
CMR3000-D0X Series
Rev. A.02
25/ 26