ELECTRICAL CHARACTERISTICS
Parameter
Supply voltage
Current consumption
Output load
PERFORMANCE CHARACTERISTICS
Parameter
Measuring range
Supply voltage
Measuring axis
Offset
Offset zero point error
Offset temperature error
Sensitivity
Sensitivity temperature error
Nonlinearity
Frequency response –3 dB
Cross-axis sensitivity
Typical values unless otherwise specifi ed.
circumstances when assembled. Please also note that you can rotate the part around the measuring plane for optimum mounting location.
Mounting position 1
(Horizontal)
Mounting position 2
(Vertical)
(2, 5
Deviation
The measuring range is limited by the sensitivity and offset.
Offset specifi ed as Output @ 0 °.
The frequency response is determined by the sensing element’s internal gas damping.
The output has true DC (0 Hz) response.
(1
(4
(5
(3
VTI Technologies reserves the right to modify this specifi cation without prior to notice.
(5
Negative incl.,
Condition
Unregulated or
regulated ratiometric
Resistive
Capacitive
Condition
(see “Directions”)
Output at 0 °
Max. deviation
0…70 °C
-25...85 °C
0…70 °C
-25...85 °C
Sinus output
Stand Alone Inclinometer
Zero position,
SCA121T-D03 SCA121T-D07 SCA121T-D05
SCA121T Series
Dual Axis Analog Output
FEATURES
• Silicon 3D MEMS sensor
• 0,1 ° accuracy
• Resolution < 0,001 °
• Operating temperature range -40...+85 °C
• Long term stability < 0,02 °
• Shock resistance >20 000 g
• Sensing element -3 dB @ 18 Hz
• Main dimensions: 30x30x13 mm size, single or dual axis
• Voltage output
• RoHS compatible
Min.
4.75
-0.8 ...0.3
-1.5 ...0.5
10
7
7 ...35
±0.2
±0.6
±
N/A
X-Y
2.5
35
18
2
3
90
1
Positive incl.
Typ
16
5
5
-0.8 ...0.3
-1.5 ...0.5
7 ...35
±
±0.2
±0.6
X-Y
2.5
70
0.1
18
4
3
30
1
Y-axis
Max.
5.25
35
20
Mounting position 1
Mounting position 2
Deviation
Note 4
Note 5
-0.8 ...0.3
-1.5 ...0.5
5
±0.2
±0.6
±
±0.25
N/A
X-Y
2.5
Units
35
18
2
3
90
1
The cross-axis sensitivity determines how much inclination, perpendicular to the measuring
axis, couples to the output.
For optimum zero point accuracy, mounting angle of the part can be adjusted.
mA
nF
V
V
Positive incl.,
Applies to: -D03, -D07
Applies to: -D05
mV/°(@offset pos.)
For customised product please contact VTI Technologies
Units
V/g
%
%
Hz
%
°
V
V
°
°
°
°
BENEFITS
• Excellent long term stability
• Sensing element controlled frequency response
• Outstanding shock durability
• Harsh environment robustness
APPLICATIONS
• Platform tilt measurement
• Equipment and instrument condition monitoring
• Inclination based position measurement
• Rotational orientation measurement
Zero position,
Negative incl.
Earth’s gravity