DS80CH11 Maxim, DS80CH11 Datasheet - Page 54

no-image

DS80CH11

Manufacturer Part Number
DS80CH11
Description
The system energy manager is a highly integrated microcontroller that provides several key features for systems including key scanning and control, battery and power management, as well as two 2-Wire serial I/O Ports
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS80CH11
Manufacturer:
DALLAS
Quantity:
1 000
Part Number:
DS80CH11
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS80CH11-E02
Manufacturer:
NEC
Quantity:
2 057
Part Number:
DS80CH11-E02
Manufacturer:
DALLAS
Quantity:
20 000
When an AMQ bit is set to 1, the corresponding activity
monitor input pin is qualified with IOR or IOW. As a
result, the corresponding AMF bit will not be set unless
the programmed state on the AMI.n pin is accompanied
8.5 AMP – ACTIVITY MONITOR POLARITY REGISTER
AMP; SFR ADDR.=094H
Read/Write Access: Unrestricted.
Initialization: 00h on any type of reset
The bits in the AMP register are used to select the polar-
ity of a valid state on the activity monitor input pins.
When an AMP bit is set to 1, a high state is selected as
8.6 AMF – ACTIVITY MONITOR FLAG REGISTER
AMF; SFR ADDR.=095H
Read/Write Access: Unrestricted.
Initialization: 00h on any type of reset
An AMF bit will be set whenever a valid state is detected
on the associated AMI.n pin. A valid state is determined
by the programming of the Activity Monitor Polarity reg-
ister and the Activity Monitor Qualifier register, both
described above. If the associated AME bit is set, the
AMF bit is enabled as an interrupt source. An SEM inter-
8.7 LED CONTROL
Part 7 can also be used to control LED’s by turning them
on or off. To turn on an LED, the Port 7.X bit must be pro-
grammed to a logic 0 allowing current to sink into the
DS80CH11. To turn off an LED the Port 7.X but must be
programmed to a logic 1, preventing any current flow
DS80CH11
011200 54/88
AMP7
AMF7
BIT 7
BIT 7
AMP6
AMF6
BIT 6
BIT 6
AMP5
AMF5
BIT 5
BIT 5
AMP4
AMF4
BIT 4
BIT 4
with a valid IOR or IOW signal. This prevents false trig-
gering of activity monitor inputs from chip select outputs
due to address decoding glitches.
valid on the corresponding AMI pin. When and AMP bit
= 0, a low state is selected as valid.
rupt will be recognized if the EAM is also set, enabling
activity monitor interrupts. Upon receiving an activity
monitor interrupt, the system should read the AMF reg-
ister to determine the source of interrupt. An AMF bit
can be cleared by writing it to a 0 to clear the interrupt
source condition. Writing a 1 has no effect.
through the LED circuit. Each Port 7 pin is capable of
sinking 10mA of current. When using this port for LED
control it is recommended that no more than 40mA of
sink current be dissipated at a time into the DS80CH11.
AMP3
AMF3
BIT 3
BIT 3
AMP2
AMF2
BIT 2
BIT 2
AMP1
AMF1
BIT 1
BIT 1
AMP0
AMF0
BIT 0
BIT 0

Related parts for DS80CH11