SAM3N2A Atmel Corporation, SAM3N2A Datasheet - Page 272

no-image

SAM3N2A

Manufacturer Part Number
SAM3N2A
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3N2A

Flash (kbytes)
128 Kbytes
Pin Count
48
Max. Operating Frequency
48 MHz
Cpu
Cortex-M3
# Of Touch Channels
23
Hardware Qtouch Acquisition
No
Max I/o Pins
47
Ext Interrupts
47
Quadrature Decoder Channels
2
Usb Speed
No
Usb Interface
No
Spi
2
Twi (i2c)
2
Uart
3
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
16
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
6
Output Compare Channels
6
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
16.5.8
Name:
Address:
Access:
Note:
• WKUPS: WKUP Wake Up Status
0 (NO) = no wake up due to the assertion of the WKUP pins has occurred since the last read of SUPC_SR.
1 (PRESENT) = at least one wake up due to the assertion of the WKUP pins has occurred since the last read of SUPC_SR.
• SMWS: Supply Monitor Detection Wake Up Status
0 (NO) = no wake up due to a supply monitor detection has occurred since the last read of SUPC_SR.
1 (PRESENT) = at least one wake up due to a supply monitor detection has occurred since the last read of SUPC_SR.
• BODRSTS: Brownout Detector Reset Status
0 (NO) = no core brownout rising edge event has been detected since the last read of the SUPC_SR.
1 (PRESENT) = at least one brownout output rising edge event has been detected since the last read of the SUPC_SR.
When the voltage remains below the defined threshold, there is no rising edge event at the output of the brownout detec-
tion cell. The rising edge event occurs only when there is a voltage transition below the threshold.
• SMRSTS: Supply Monitor Reset Status
0 (NO) = no supply monitor detection has generated a core reset since the last read of the SUPC_SR.
1 (PRESENT) = at least one supply monitor detection has generated a core reset since the last read of the SUPC_SR.
• SMS: Supply Monitor Status
0 (NO) = no supply monitor detection since the last read of SUPC_SR.
1 (PRESENT) = at least one supply monitor detection since the last read of SUPC_SR.
• SMOS: Supply Monitor Output Status
0 (HIGH) = the supply monitor detected VDDIO higher than its threshold at its last measurement.
1 (LOW) = the supply monitor detected VDDIO lower than its threshold at its last measurement.
272
272
WKUPIS15
WKUPIS7
OSCSEL
31
23
15
7
Because of the asynchronism between the Slow Clock (SCLK) and the System Clock (MCK), the status register flag reset is
taken into account only 2 slow clock cycles after the read of the SUPC_SR.
SAM3N
SAM3N
Supply Controller Status Register
WKUPIS14
WKUPIS6
SMOS
30
22
14
0x400E1424
6
SUPC_SR
Read-write
WKUPIS13
WKUPIS5
SMS
29
21
13
5
WKUPIS12
WKUPIS4
SMRSTS
28
20
12
4
WKUPIS11
BODRSTS
WKUPIS3
27
19
11
3
WKUPIS10
WKUPIS2
SMWS
26
18
10
2
WKUPIS9
WKUPIS1
WKUPS
25
17
9
1
11011A–ATARM–04-Oct-10
11011A–ATARM–04-Oct-10
WKUPIS8
WKUPIS0
24
16
8
0

Related parts for SAM3N2A