Specifications of PSB 21393 H V1.3

Function
CODEC
Interface
IOM-2, SCI, UPN
Number Of Circuits
1
Voltage - Supply
3.3V, 5V
Current - Supply
27mA
Mounting Type
Surface Mount
Package / Case
44-BQFP
Includes
Activation and Deactivation, Channel Handler, DTMF / Tone / Ringing Generator, HDLC Controller, Speakerphone, UPN Transceiver
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Operating Temperature
-
Other names
PSB21393HV1.3XT
PSB21393HV13XP
SP000007533
SP000007534
The MONITOR transfer protocol rules are summarized in the following section
• A pair of MX and MR in the inactive state for two or more consecutive frames indicates
• A start of a transmission is initiated by the transmitter by setting the MXC bit to ’1’
• The internal MX,MR control indicates or acknowledges a new byte in the MON slot by
• Two frames with the MX-bit in the inactive state indicate the end of transmission.
• Two frames with the MR-bit set to inactive indicate a receiver request for abort.
• The transmitter can delay a transmission sequence by sending the same byte
• Since a double last-look criterion is implemented the receiver is able to receive the
• To control this handshake procedure a collision detection mechanism is implemented
• Monitor data will be transmitted repeatedly until its reception is acknowledged or the
• Two frames with the MX bit in the inactive state indicates the end of a message
• Transmission and reception of monitor messages can be performed simultaneously.
2.2.4.2
In case the SCOUT does not detect identical monitor messages in two successive
frames, transmission is not aborted. Instead the SCOUT will wait until two identical bytes
are received in succession.
A transmission is aborted by the SCOUT if
• an error in the MR handshaking occurs
• a collision on the IOM bus of the MONITOR data or MX bit occurs
• the transmission time-out timer expires
A reception is aborted by the SCOUT if
• an error in the handshaking occurs or
• an abort request from the opposite device occurs
Data Sheet
an idle state or an end of transmission.
enabling the internal MX control. The receiver acknowledges the received first byte by
setting the MR control bit to ’1’ enabling the internal MR control.
toggling MX,MR from the active to the inactive state for one frame.
continuously. In that case the MX-bit remains active in the IOM-2 frame following the
first byte occurrence.
MON slot data at least twice (in two consecutive frames). The receiver acknowledge
the data after the reception of two identical bytes in two successive frames.
in the transmitter. This is done by making a collision check per bit on the transmitted
MONITOR data and the MX bit.
transmission time-out timer expires.
(EOM).
This feature is used by the SCOUT to send back the response before the transmission
from the controller is completed (the SCOUT does not wait for EOM from the
controller). MONITOR control commands nevertheless are processed sequential that
means e.g. during a read on a register no further command is executed.
Error Treatment
49
PSB 21391
PSB 21393
Interfaces
2001-03-07