PSB2163T-V31TR Infineon Technologies, PSB2163T-V31TR Datasheet - Page 80

no-image

PSB2163T-V31TR

Manufacturer Part Number
PSB2163T-V31TR
Description
IC AUDIO RINGING CODEC 28-PDSO
Manufacturer
Infineon Technologies
Series
ARCOFI®r
Datasheet

Specifications of PSB2163T-V31TR

Function
CODEC Filter
Interface
IOM-2, PCI, Serial
Number Of Circuits
1
Voltage - Supply
5V
Current - Supply
900µA
Power (watts)
1mW
Operating Temperature
-25°C ~ 80°C
Mounting Type
Surface Mount
Package / Case
DSO-28
Includes
Activation and Deactivation, B-Channel and D-Channel HDLC Controllers, D-Channel Priority Handler, Monitor Channel Handler
Lead Free Status / RoHS Status
Request inventory verification / Request inventory verification
Other names
PSB2163T-V31INTR
PSB2163T-V31TR
3.3
The most currently used ARCOFI-operating modes are documented in the following
table. The 12 ARCOFI-configuration registers have enough build-in flexibility to
accommodate an extensive set of user calling procedures.
The following operating mode description table is not exhaustive but should be used as
an example of possible functions performed by the ARCOFI.
State
POR
STAND BY
HANDSET
RINGING
DTMF
PULSE DIAL
LOUD HEARING
(MONITORING)
Semiconductor Group
ARCOFI
®
Operating Modes
Description
Power-on reset: when power is supplied to the ARCOFI an
internal power-on reset is generated. In addition a hardware reset
via an RC-network connected to input pin RS will force all
ARCOFI internal registers to default values. The
ARCOFI-registers reset state is described in section 3.1 and 4.
The system microprocessor can initialize the ARCOFI via the
IOM-2 or the SCI-bus with a different set of filter and
configuration values. Whilst remaining in power-down
(GCR.PU = 0) a new set of filter coefficients and configuration
bits can be loaded in the ARCOFI.
The system MPU detects activity from the hookswitch or from the
keyboard. The ARCOFI can be placed in HANDSET state where
all handset l/O are enabled (AMI & AHO activated).
The system MPU detects an incoming call, the ARCOFI can be
placed in a RINGING state by activating the tone ringer via
TGCR/TGSR and configuring the ARCOFI such that either the
LSP/LSN-output or the piezo output (pins PZ1/PZ2) are enabled.
An emergency ringing is also implemented. In this mode, only the
tone ringer and the loudspeaker amplifier are active (AMI- and
AHO-amplifier are disabled by the user). The tone ringer signal is
directly switched to the loudspeaker amplifier ALS.
All audio inputs can be disabled by forcing the AMI-amplifier
(ATCR) to power-down. DTMF tones are generated with the tone
generator and are output to the transmit path.
Handset audio path can be enabled by forcing a HANDSET
mode. A single tone can be superimposed into the audio receive
path so as to provide audible feedback when dialling.
The handset l/O and the loudspeaker outputs LSP/LSN are
active (ATCR & ARCR).
79
Operational Description

Related parts for PSB2163T-V31TR