C8051F317-GMR Silicon Laboratories Inc, C8051F317-GMR Datasheet - Page 147

no-image

C8051F317-GMR

Manufacturer Part Number
C8051F317-GMR
Description
MCU 8-Bit C8051F31x 8051 CISC 16KB Flash 3.3V 24-Pin QFN EP T/R
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of C8051F317-GMR

Package
24QFN EP
Device Core
8051
Family Name
C8051F31x
Maximum Speed
25 MHz
Ram Size
1.25 KB
Program Memory Size
16 KB
Operating Supply Voltage
3.3 V
Data Bus Width
8 Bit
Program Memory Type
Flash
Number Of Programmable I/os
21
Interface Type
I2C/SMBus/SPI/UART
On-chip Adc
17-chx10-bit
Operating Temperature
-40 to 85 °C
Number Of Timers
4

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F317-GMR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Company:
Part Number:
C8051F317-GMR
Quantity:
1 500
Company:
Part Number:
C8051F317-GMR
Quantity:
398
C8051F310/1/2/3/4/5/6/7
The direction bit (R/W) occupies the least-significant bit position of the address byte. The direction bit is set
to logic 1 to indicate a "READ" operation and cleared to logic 0 to indicate a "WRITE" operation.
All transactions are initiated by a master, with one or more addressed slave devices as the target. The
master generates the START condition and then transmits the slave address and direction bit. If the trans-
action is a WRITE operation from the master to the slave, the master transmits the data a byte at a time
waiting for an ACK from the slave at the end of each byte. For READ operations, the slave transmits the
data waiting for an ACK from the master at the end of each byte. At the end of the data transfer, the master
generates a STOP condition to terminate the transaction and free the bus. Figure 14.3 illustrates a typical
SMBus transaction.
SCL
SDA
SLA6
SLA5-0
R/W
D7
D6-0
START
Slave Address + R/W
ACK
Data Byte
NACK
STOP
Figure 14.3. SMBus Transaction
14.3.1. Arbitration
A master may start a transfer only if the bus is free. The bus is free after a STOP condition or after the SCL
and SDA lines remain high for a specified time (see
Section “14.3.4. SCL High (SMBus Free) Timeout”
on page
148). In the event that two or more devices attempt to begin a transfer at the same time, an arbi-
tration scheme is employed to force one master to give up the bus. The master devices continue transmit-
ting until one attempts a HIGH while the other transmits a LOW. Since the bus is open-drain, the bus will
be pulled LOW. The master attempting the HIGH will detect a LOW SDA and lose the arbitration. The win-
ning master continues its transmission without interruption; the losing master becomes a slave and
receives the rest of the transfer if addressed. This arbitration scheme is non-destructive: one device
always wins, and no data is lost.
Rev. 1.7
147

Related parts for C8051F317-GMR