RFW-D100 Vishay, RFW-D100 Datasheet - Page 8

no-image

RFW-D100

Manufacturer Part Number
RFW-D100
Description
Manufacturer
Vishay
Datasheet

Specifications of RFW-D100

Operating Temperature (min)
0C
Operating Temperature (max)
70C
Operating Temperature Classification
Commercial
Package Type
LQFP
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.6V
Lead Free Status / Rohs Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RFW-D100-LF
Manufacturer:
CTC
Quantity:
3 186
RFW-D100
Vishay RFWaves
RESET
A reset is achieved by holding the RST pin high for at
least 10 oscillator cycles. The reset initializes the
RFW-D100 and all of its registers to their initial state.
To ensure good power up, a reset should be given to
the RFW-D100 after power up.
POWER SAVING MODES
The RFW-D100 was designed to work in similar
working modes as the typical MCU.
These modes enable the system to save power when
the RFW-D100 is not in use.
POWER DOWN MODE
The MCU is able to halt all activity in the RFW-D100 by
stopping its clock. This enables the MCU to reduce the
power consumption of the RFW-D100 to a minimum.
All registers and FIFOs retain their values when the
RFW-D100 is in power-down mode.
In
IDLE_MODE=‘1’, and IDLE_RST=‘0’.
If the MCU wants to put the RFW-D100 into power-
down mode, it should do the following:
1. IDLE_MODE = ‘0’.
2. WAIT 10 µs.
3. POWER_DOWN = ‘0’.
4. POWER_DOWN pin should be kept low as long as
5. IDLE_MODE = ‘1’ – So this input will be compatible
www.vishay.com
8
OSCILLATOR CHARACTERISTICS
the RFW-D100 is in power down mode.
with its internal pull up to lower power consumption
in power down mode.
working
mode:
POWER_DOWN=‘1’,
For more information please contact: RFTransceivers@vishay.com
RFW-D100
Figure 4. RFW-D100’s Oscillator Topology
Inside
C1
(PIN 44)
OSC_I
Crystal
Rfeb
If the MCU wants to wake the RFW-D100 from
power-down mode back to working mode, it should do
the following:
1. IDLE_RST = ‘1’.
2. IDLE_MODE = ‘0’.
3. POWER_DOWN = ‘1’.
4. WAIT Oscillator Wakeup Time until oscillator is
5. IDLE_RST = ‘0’.
6. IDLE_MODE = ‘1’.
7. Exit ‘Low Mode’.
The wakeup time of the RFW-D100 from power-down
mode to fully operating mode is depended on the
crystal type. Typically it should be a few milliseconds.
Since the RFW-D100 retains all the register values in
power-down mode, special attention should be paid to
the register values before it enters power-down. For
example, the MCU should check that the RFW-D100 is
not in the middle of transmitting or receiving a packet.
The RFACTIVE should be set low to shut down the
RFW122, before entering power down mode.
Power consumption in power down mode is < 1 µA, if
RC_OSC is disabled.
Power consumption in power down mode is < 10 µA, if
RC_OSC is enabled.
OSC_IO
(PIN 43)
stable.
Rd
C2
19313
Document Number 84675
Rev. 1.1, 22-Jan-07

Related parts for RFW-D100