Windowing
A fully configurable window can be selected for readout.
The parameters to configure this window are:
cycle. The granularity of configuring the X start position is
also 24. Every value written to the windowX_2 register must
be multiplied by 24 to find the corresponding column in the
pixel array.
(x_kernels*24 in full frame mode) in subsampling mode
x_kernels*48 represents the number of columns over which
subsampling is done. The x_kernels value must be written
to the windowX_4 register.
granularity of 1. Note that in subsample mode, the correct
y_start position must be uploaded (exact value depends on
color or B/W subsampling mode). This value must be
written to the windowX_1 and windowx_2 register.
x_start. The sensor reads out 24 pixels in one single clock
x_kernels. The number of columns that is read out
y_start. The starting line of the readout window,
y
y
star
en
t
d
x start
Figure 23. Window Selected for Readout
ADDITIONAL FEATURES
xkernel
http://onsemi.com
1280 ixels
p
29
1. In all cases (even in reverse scan), y_end are larger than
y_start. Note that in subsample mode, the correct y_end
position must be uploaded (exact value depends on color or
B/W subsampling mode). This value must be written to the
windowX_3 and windowX_4 register.
than in full frame mode, because only the relevant part of the
image array is accessed. As a result, it is possible to achieve
higher frame rates.
Subsampling
constant field of view and an increased frame rate.
LUPA1300-2 supports monochrome and color subsampling
modes of operation. The pixel order for one complete row is
shown in Table 18 and Table 19 on page 26.
y_end. The end line of the readout window, granularity of
In case of windowing, the effective readout time is smaller
Subsampling reduces resolution while maintaining the
1024 ixels