PI7C9X7954AFDE Pericom Semiconductor, PI7C9X7954AFDE Datasheet - Page 40

no-image

PI7C9X7954AFDE

Manufacturer Part Number
PI7C9X7954AFDE
Description
IC PCIE-TO-UART BRIDGE 128LQFP
Manufacturer
Pericom Semiconductor
Datasheets

Specifications of PI7C9X7954AFDE

Applications
PCIe-to-Uart Bridge
Interface
Advanced Configuration Power Interface (ACPI)
Voltage - Supply
1.8V, 3.3V
Package / Case
128-LQFP
Mounting Type
Surface Mount
Transmitter And Receiver Fifo Counter
Yes
Package Type
LQFP
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Operating Temperature Classification
Industrial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PI7C9X7954AFDE
Manufacturer:
PERICOM
Quantity:
2
Part Number:
PI7C9X7954AFDE
Manufacturer:
Pericom
Quantity:
197
Part Number:
PI7C9X7954AFDE
Manufacturer:
Pericom
Quantity:
10 000
Company:
Part Number:
PI7C9X7954AFDE
Quantity:
48
6.2.60. UNCORRECTABLE ERROR MASK REGISTER – OFFSET 108h
September 2009 – Revision 1.3
Pericom Semiconductor
BIT
13
14
15
16
17
18
19
20
31:21
BIT
0
3:1
4
11:5
12
13
14
15
16
FUNCTION
Flow Control
Protocol Error
Status
Completion
Timeout Status
Completer Abort
Status
Unexpected
Completion Status
Receiver Overflow
Status
Malformed TLP
Status
ECRC Error Status
Unsupported
Request Error
Status
Reserved
FUNCTION
Training Error
Mask
Reserved
Data Link Protocol
Error Mask
Reserved
Poisoned TLP Mask
Flow Control
Protocol Error
Mask
Completion
Timeout Mask
Completer Abort
Mask
Unexpected
Completion Mask
09-0088
RW1CS
RW1CS
RW1CS
RW1CS
RW1CS
RW1CS
RW1CS
RW1CS
TYPE
TYPE
RWS
RWS
RWS
RWS
RWS
RWS
RWS
RO
RO
RO
Page 40 of 70
DESCRIPTION
When set, the Training Error event is not logged in the Header Log
register and not issued as an Error Message to RC either.
Reset to 0b.
Reset to 000b.
When set, the Data Link Protocol Error event is not logged in the
Header Log register and not issued as an Error Message to RC either.
Reset to 0b.
Reset to 0000000b.
When set, an event of Poisoned TLP has been received or generated
is not logged in the Header Log register and not issued as an Error
Message to RC either.
Reset to 0b.
When set, the Flow Control Protocol Error event is not logged in the
Header Log register and not issued as an Error Message to RC either.
Reset to 0b.
When set, the Completion Timeout event is not logged in the Header
Log register and not issued as an Error Message to RC either.
Reset to 0b.
When set, the Completer Abort event is not logged in the Header Log
register and not issued as an Error Message to RC either.
Reset to 0b.
When set, the Unexpected Completion event is not logged in the
Header Log register and not issued as an Error Message to RC either.
Reset to 0b.
DESCRIPTION
When set, indicates that the Flow Control Protocol Error event has
occurred.
Reset to 0b.
When set, indicates that the Completion Timeout event has occurred.
Reset to 0b.
When set, indicates that the Completer Abort event has occurred.
Reset to 0b.
When set, indicates that the Unexpected Completion event has
occurred.
Reset to 0b.
When set, indicates that the Receiver Overflow event has occurred.
Reset to 0b.
When set, indicates that a Malformed TLP has been received.
Reset to 0b.
When set, indicates that an ECRC Error has been detected.
Reset to 0b.
When set, indicates that an Unsupported Request event has occurred.
Reset to 0b.
Reset to 000h.
PCI Express® Quad UART
PI7C9X7954
Datasheet

Related parts for PI7C9X7954AFDE