IDT82V1054APF IDT, Integrated Device Technology Inc, IDT82V1054APF Datasheet - Page 27

IC PCM CODEC 4CH MPI 3.3V 64TQFP

IDT82V1054APF

Manufacturer Part Number
IDT82V1054APF
Description
IC PCM CODEC 4CH MPI 3.3V 64TQFP
Manufacturer
IDT, Integrated Device Technology Inc
Type
Line Interface Units (LIUs)r
Datasheet

Specifications of IDT82V1054APF

Voltage - Supply
3.135 V ~ 3.465 V
Mounting Type
Surface Mount
Package / Case
64-TQFP, 64-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Drivers/receivers
-
Protocol
-
Other names
82V1054APF

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT82V1054APF
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82V1054APF8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82V1054APFG
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82V1054APFG8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
IDT82V1054A QUAD PROGRAMMABLE PCM CODEC WITH MPI INTERFACE
GREG22: Global Loopback Control and PLL Power Down, Read/Write (35H/B5H)
The Level Meter Channel Select bits (CS[1:0]) select a channel, data on which will be level metered.
CS[1:0] = 00:
CS[1:0] = 01:
CS[1:0] = 10:
CS[1:0] = 11:
The PLL Power Down bit (PPD) controls the operation state of the PLL block.
PPD = 0:
PPD = 1:
The Loop Control bits determine the loopback status. Refer to
DLB_ANA = 0:
DLB_ANA = 1:
ALB_8k = 0:
ALB_8k = 1:
DLB_8k = 0:
DLB_8k = 1:
DLB_DI = 0:
DLB_DI = 1:
ALB_DI = 0:
ALB_DI = 1:
Command
I/O data
R/W
b7
Reserved
Channel 1 is selected (default);
Channel 2 is selected;
Channel 3 is selected;
Channel 4 is selected.
The PLL is disabled. The device is in normal operation state (default);
The PLL is powered down. The device works in power-saving mode. All clocks stop running.
The Digital Loopback via Analog Interface is disabled (default);
The Digital Loopback via Analog Interface is enabled.
The Analog Loopback via 8 kHz Interface is disabled (default);
The Analog Loopback via 8 kHz Interface is enabled.
The Digital Loopback via 8 kHz Interface is disabled (default);
The Digital Loopback via 8 kHz Interface is enabled.
The Digital Loopback from DR to DX is disabled (default);
The Digital Loopback from DR to DX is enabled.
The Analog Loopback from DX to DR is disabled (default);
The Analog Loopback from DX to DR is enabled.
b6
0
PPD
b5
1
DLB_ANA
27
b4
1
Figure - 4 on page 11
ALB_8k
b3
0
for detailed information.
DLB_8k
b2
1
DLB_DI
b1
INDUSTRIAL TEMPERATURE
0
ALB_DI
b0
1

Related parts for IDT82V1054APF