IDT82V1054APF IDT, Integrated Device Technology Inc, IDT82V1054APF Datasheet - Page 26

IC PCM CODEC 4CH MPI 3.3V 64TQFP

IDT82V1054APF

Manufacturer Part Number
IDT82V1054APF
Description
IC PCM CODEC 4CH MPI 3.3V 64TQFP
Manufacturer
IDT, Integrated Device Technology Inc
Type
Line Interface Units (LIUs)r
Datasheet

Specifications of IDT82V1054APF

Voltage - Supply
3.135 V ~ 3.465 V
Mounting Type
Surface Mount
Package / Case
64-TQFP, 64-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Drivers/receivers
-
Protocol
-
Other names
82V1054APF

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT82V1054APF
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82V1054APF8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82V1054APFG
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82V1054APFG8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
IDT82V1054A QUAD PROGRAMMABLE PCM CODEC WITH MPI INTERFACE
GREG13: Reserved for future use.
GREG14: Reserved for future use.
GREG15: Reserved for future use.
GREG16: Reserved for future use.
GREG17: Reserved for future use.
GREG18: Level Meter Result Low Byte, Read Only (31H)
GREG19: Level Meter Result High Byte, Read Only (32H)
GREG20: Level Meter Count Number, Read/Write (33H/B3H)
GREG21: Level Meter Channel and Linear/Compressed Mode Selection, Level Meter On/Off, Read/Write (34H/B4H)
pins respectively. When the SB3 pins of Channel 1 to Channel 4 are configured as outputs, the control data is written to these four SB3
pins via the SB3[0] to SB3[3] bits respectively.
This register contains the low byte of the level meter result. The default value is 00H.
The LVLL[0] bit in this register will be set to ‘1’ when the level meter result (both high and low bytes) is ready, and it will be reset to ‘0’
immediately after the high byte of result is read. To read the level meter result, it is recommended to the low byte first, then read the high
byte (LVLH[7:0] in GREG19).
This register contains the high byte of the level meter result. The default value is 00H.
The CN[7:0] bits are used to set the number of time cycles for sampling the PCM data.
CN[7:0] = 0 (d):
CN[7:0] = N (d):
The Level Meter On/Off bit (LMO) enables/disables the level meter.
LMO = 0:
LMO = 1:
The Linear/Compressed bit (L/C) determines the mode of level meter operation.
L/C = 0:
L/C = 1:
GREG18 and GREG19.
Command
Command
Command
Command
I/O data
I/O data
I/O data
I/O data
LVLH[7]
LVLL[7]
CN[7]
R/W
R/W
b7
b7
b7
b7
0
0
the PCM data is output to the result registers GREG18 and GREG19 directly;
the PCM data is sampled for N × 125
The level meter is disabled (default);
The level meter is enabled.
Message mode is selected. The compressed PCM data will be output to GREG19 transparently (default).
Metering mode is selected. The linear PCM data will be metered and the result will be output to the registers
LVLH[6]
LVLL[6]
CN[6]
b6
b6
b6
b6
0
0
0
0
Reserved
LVLH[5]
LVLL[5]
CN[5]
b5
b5
b5
b5
1
1
1
1
LVLH[4]
LVLL[4]
CN[4]
26
b4
b4
b4
b4
1
1
1
1
µ
s (N is from 1 to 255).
LVLH[3]
LVLL[3]
CN[3]
LMO
b3
b3
b3
b3
0
0
0
0
LVLH[2]
LVLL[2]
CN[2]
L/C
b2
b2
b2
b2
0
0
0
1
LVLH[1]
LVLL[1]
CN[1]
CS[1]
b1
b1
b1
b1
INDUSTRIAL TEMPERATURE
0
1
1
0
LVLH[0]
LVLL[0]
CN[0]
CS[0]
b0
b0
b0
b0
1
0
1
0