PIC18F25K22-I/SP Microchip Technology Inc., PIC18F25K22-I/SP Datasheet - Page 221

no-image

PIC18F25K22-I/SP

Manufacturer Part Number
PIC18F25K22-I/SP
Description
32KB, Flash, 1536bytes-RAM, 8-bit Family, nanoWatt XLP, 28 SPDIP .300in TUBE
Manufacturer
Microchip Technology Inc.
Datasheet

Specifications of PIC18F25K22-I/SP

A/d Inputs
17-Channel, 10-Bit
Comparators
2
Cpu Speed
16 MIPS
Eeprom Memory
256 Bytes
Input Output
24
Interface
I2C/SPI/UART/USART
Memory Type
Flash
Number Of Bits
8
Package Type
28-pin SPDIP
Programmable Memory
32K Bytes
Ram Size
1.5K Bytes
Speed
64 MHz
Temperature Range
–40 to 125 °C
Timers
3-8-bit, 4-16-bit
Voltage, Range
1.8-5.5 V
Lead Free Status / Rohs Status
RoHS Compliant part Electrostatic Device

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18F25K22-I/SP
Manufacturer:
MICROCHIP
Quantity:
1 200
15.4.5 START CONDITION
The I
transition of SDAx from a high-to -low state while
SCLx line is high. A Start condition is always gener-
ated by the master and signifies the transition of the
bus from an Idle to an active state.
shows wave forms for Start and Stop conditions.
A bus collision can occur on a Start condition if the
module samples the SDAx line low before asserting it
low. This does not conform to the I
states no bus collision can occur on a Start.
15.4.6 STOP CONDITION
A Stop condition is a transition of the SDAx line from a
low-to-high state while the SCLx line is high.
FIGURE 15-12:
FIGURE 15-13:
 2010 Microchip Technology Inc.
Note: At least one SCLx low time must appear
2
C specification defines a Start condition as a
before a Stop is valid, therefore, if the SDAx
line goes low then high again while the SCLx
line stays high, only the Start condition is
detected.
SDAx
SCLx
I
I
2
2
C™ START AND STOP CONDITIONS
C™ RESTART CONDITION
Condition
Start
S
2
C specification that
Data Allowed
Data Allowed
Figure 15-10
Change of
Change of
Preliminary
Condition
Restart
Sr
15.4.7 RESTART CONDITION
A Restart is valid any time that a Stop would be valid.
A master can issue a Restart if it wishes to hold the
bus after terminating the current transfer. A Restart
has the same effect on the slave that a Start would,
resetting all slave logic and preparing it to clock in an
address. The master may want to address the same or
another slave.
In 10-bit Addressing Slave mode a Restart is required
for the master to clock data out of the addressed slave.
Once a slave has been fully addressed, matching both
high and low address bytes, the master can issue a
Restart and the high address byte with the R/W bit set.
The slave logic will then hold the clock and prepare to
clock out data.
After a full match with R/W clear in 10-bit mode, a prior
match flag is set and maintained. Until a Stop
condition, a high address with R/W clear, or high
address match fails.
15.4.8 START/STOP CONDITION
The SCIE and PCIE bits of the SSPxCON3 register
can enable the generation of an interrupt in Slave
modes that do not typically support this function. Slave
modes where interrupt on Start and Stop detect are
already enabled, these bits will have no effect.
PIC18(L)F2X/4XK22
Data Allowed
Change of
Data Allowed
INTERRUPT MASKING
Change of
Condition
Stop
P
DS41412D-page 221