ICS1893Y-10 IDT, Integrated Device Technology Inc, ICS1893Y-10 Datasheet - Page 126

PHYCEIVER LOW PWR 3.3V 64-TQFP

ICS1893Y-10

Manufacturer Part Number
ICS1893Y-10
Description
PHYCEIVER LOW PWR 3.3V 64-TQFP
Manufacturer
IDT, Integrated Device Technology Inc
Series
PHYceiver™r
Type
PHY Transceiverr
Datasheets

Specifications of ICS1893Y-10

Protocol
MII
Voltage - Supply
3.14 V ~ 3.47 V
Mounting Type
Surface Mount
Package / Case
64-TQFP, 64-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Drivers/receivers
-
Lead Free Status / Rohs Status
Not Compliant
Other names
1893Y-10
800-1934-5
ICS1893Y-10

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICS1893Y-10
Manufacturer:
ICS
Quantity:
10 201
Part Number:
ICS1893Y-10
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
ICS1893Y-10
Manufacturer:
ICS
Quantity:
1 000
Part Number:
ICS1893Y-10
Manufacturer:
ICS
Quantity:
20 000
Company:
Part Number:
ICS1893Y-10
Quantity:
80
Part Number:
ICS1893Y-10LF
Manufacturer:
ICS
Quantity:
5 978
Part Number:
ICS1893Y-10LF
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
ICS1893Y-10LFT
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
ICS1893Y-10T
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
9.5.2 Timing for Transmit Clock (TXCLK) Pins
ICS1893Y-10 Rev F 1/20/04
TXCLK
Table 9-9
interfaces.
Table 9-9. Transmit Clock Timing
Figure 9-3. Transmit Clock Timing Diagram
Period
Time
t2a
t2b
t2c
t2d
t1
ICS1893Y-10 Data Sheet - Release
lists the significant time periods for signals on the Transmit Clock (TXCLK) pins for the various
TXCLK Duty Cycle
TXCLK Period
TXCLK Period
TXCLK Period
TXCLK Period
Figure 9-3
Parameter
shows the timing diagram for the time periods.
Copyright © 2004, Integrated Circuit Systems, Inc.
100M MII (100Base-TX)
10M MII (10Base-T)
100M Symbol Interface (100Base-TX)
10M Serial Interface (10Base-T)
All rights reserved.
t1
126
Conditions
t2x
Chapter 9 DC and AC Operating Conditions
Min.
35
Typ. Max. Units
400
100
50
40
40
January, 2004
65
ns
ns
ns
ns
%

Related parts for ICS1893Y-10