E-STE100P STMicroelectronics, E-STE100P Datasheet - Page 19

IC TRANSCEIVER 3.3V 64 TQFP

E-STE100P

Manufacturer Part Number
E-STE100P
Description
IC TRANSCEIVER 3.3V 64 TQFP
Manufacturer
STMicroelectronics
Type
Transceiverr
Datasheet

Specifications of E-STE100P

Number Of Drivers/receivers
1/1
Protocol
MII
Voltage - Supply
3.15 V ~ 3.45 V
Mounting Type
Surface Mount
Package / Case
64-TQFP, 64-VQFP
Number Of Receivers
1
Data Rate
10/100Mbps
Operating Supply Voltage (typ)
3.3V
Package Type
TQFP
Operating Temperature Classification
Industrial
Operating Supply Voltage (max)
3.45V
Operating Supply Voltage (min)
3.15V
Mounting
Surface Mount
Pin Count
64
Operating Temperature (max)
85C
Operating Temperature (min)
-40C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-2143
STE100P

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E-STE100P
Manufacturer:
ST
Quantity:
310
Part Number:
E-STE100P
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
E-STE100P
Manufacturer:
ST
0
Note:
The above LED connections are recommended for setting a Logic Level 1 or Logic Level 0 on the
STE100P LED/PHY Address pins, for determining PHY address.
7.11 Preamble Suppression
Preamble suppression mode in the STEPHY1 is indicated by a one in bit six of the PR1 Register. If it is
determined that all PHY devices in the system support preamble suppression, then a preamble is not nec-
essary for each management transaction. The first transaction following power-up/hardware reset re-
quires 32 bits of preamble. The full 32 bit preamble is not required for each additional transaction. The
STEPHY1 will respond to management accesses without preamble, but a minimum of one idle bit between
management transactions is required as specified in IEEE 802.3u.
7.12 Remote Fault
The remote fault function indicates to a link partner that a fault condition has occurred by using the Remote
Fault bit, which is encoded in bit 13 of the Link Code Word. A local device indicates to its link partner that
it has found a fault by setting the Remote Fault bit in the Auto-Negotiation register to logic one and rene-
gotiating with the link partner. The Remote Fault bit remains at logic one until successful negotiation with
the Link Code Word occurs. The bit will then return to 0. When the message is sent that the Remote Fault
bit is set to logic one, the device will set the Remote Fault bit in the MII to logic one if the management
function is present.
7.13 Transmit Isolation
Figure 7.
RxD
TxD
4/5
4/5
STA/STE
MII
STEPHY1
TX(100MHz)/TP(10MHz)
Ethernet
ttp
tpn
STE100P
19/31