MSO-0011P-012

Manufacturer Part Number
MSO-0011P-012
Description
Socket, Relay; 11 Pin Octal, ID# SR3P-06
Manufacturer
NCC
Type
Octalr
Datasheet

Specifications of MSO-0011P-012

Number Of Contacts
11
Time Range
0.05 Sec. to 999 Min.
Output Rating
10 A @ 240 VAC Max.; 100 mA @ 5 VDC Min.
Operating Temperature
–23°C to +55°C
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
4-8
Pulse Jet Dust Collector Control with Extended Cycle
DNC-T2110 Series
FEATURES
LOGIC FUNCTION DIAGRAM
SWITCH
INPUT
OFF DELAY
PRESSURE
OUTPUTS
OUTPUT 1
OUTPUT 2
OUTPUT 8
VOLTAGE
Digital Timing Circuitry: allows for sta-
ble timing from -40°C to 65°C tempera-
ture range
Pulse Time: line synchronized to elimi-
nate 8 millisecond triac turn off variation
10 A-400/600V Output Triacs: for maxi-
mum protection against output shorts;
200 VA load rating
Conformally coated for protection
against vibration, humidity, and con-
tamination
2 Modes of Operation: can be operated
Continuously or On Demand via external
pressure switch
Extended cycle capability for added
pulses after pressure switch opens
Field Selectable: for numbers of outputs
required
LED Indicators: for compartment being
cleaned indication
Rugged Timing Adjustments: large sta-
ble potentiometers are used for ON and
OFF time adjustments
Metal Chassis Provided: for mounting
directly into NEMA 4 box
Timer Functionally Tested: to eliminate
field failures
Input Protection: 30 joule metal oxide
varistor
One Year Warranty: warranted to be free
from defects in materials or workmanship
for one year from date of manufacture
DUST COLLECTOR CONTROLS
DISABLED
ENABLED
CLOSED
OPEN
PULSE
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
TIME
OFF
TIME
OFF
ON TIME
ON TIME
TIME
OFF
OFF TIME
ON TIME
ON TIME
Operating Logic: The DNC-T2110-A10/
B10 are ten output sequencer, cycle tim-
ers with adjustable ON-TIME, OFF-TIME
and DELAY times. When voltage is applied
to L1 and L2 and the pressure switch is
closed, the OFF-TIME is started, At the
end of the preset OFF-TIME the control
will cycle through the outputs until the
pressure switch opens. The ENABLE/
DISABLE switch on the control can enable
the OFF-DELAY. When the pressure switch
opens and the OFF-DELAY is enabled, then
the OFF-DELAY time is started and the
OFF-TIME, ON-TIME cycles will continue
until the end of the OFF DELAY time. If the
OFF-DELAY times out during the ON-TIME,
the control will allow the ON-TIME to time
out. Upon closing of the pressure switch
the control will commence the OFF-TIME,
ON-TIME sequence on the next output and
the OFF-DELAY time will reset. If the pres-
sure switch is closed during the OFF-DELAY
time, the control will reset the OFF-DELAY.
The ENABLE/DISABLE switch on the con-
trol can disable the OFF-DELAY. When the
OFF-DELAY is disabled and the pressure
switch opens, during the ON-TIME, the
control will allow the ON-TIME to time out.
Upon closing of the pressure switch the
control will commence the OFF-TIME, ON-
TIME sequence on the next output.