MSO-0011P-012 NCC, MSO-0011P-012 Datasheet - Page 13

no-image

MSO-0011P-012

Manufacturer Part Number
MSO-0011P-012
Description
Socket, Relay; 11 Pin Octal, ID# SR3P-06
Manufacturer
NCC
Type
Octalr
Datasheet

Specifications of MSO-0011P-012

Number Of Contacts
11
Time Range
0.05 Sec. to 999 Min.
Output Rating
10 A @ 240 VAC Max.; 100 mA @ 5 VDC Min.
Operating Temperature
–23°C to +55°C
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
Multi-Time Range/Function/Input Voltage
1/16 DIN TMM Series
FEATURES
The TMM Series offers selectable multiple
time ranges, functional logic modes and
universal input voltage range, all in one
plug-in 1/16 DIN style panel mountable
package.
two multi-position rotary switches. One
switch selects one of six time ranges. The
other switch selects one of five operating
logic modes. A 3-digit push-button switch
selects the amount of time required for a
timing cycle.
Note: 1) Do not apply voltage or ground to the start switch,
2) Switch leads should be shielded when running close to other
wires (Start switch suppled by customer)
SPECIFICATIONS
TIME DELAY
Adjustment: 3 digit push-button switch
Range: .05 seconds to 999 hours in 6 ranges
Repeatability: ±0.1% of set time or ±20 ms
whichever is greater
Accuracies: All functions ±1% of set time or ±20
ms whichever is greater
INPUT
Operating Voltage: 24 to 240 VAC ±15%, 50/60
Hz; 24 to 240 VDC ±15%, (DC unfiltered input
voltage must be full-wave rectified)
Power On Response: 50 ms max.
Power Off Reset Time: Requires power interrup-
tion of 150 ms max. (50 ms typical)
Start Switch Closure Time: 50 ms min. to initi-
ate timing cycle; 50 ms min. to reset delay during
timing cycle
Power Consumption: 14 VA max. at 276 VAC,
2.5 VA max. at 24 VAC
Programming is accomplished by using
100% functionally tested
1/16 DIN panel mountable enclosure
Universal input voltage
Microprocessor controlled timing circuit
Five logic modes, user selectable
Six time ranges, user selectable
Time cycles from 50 ms to 999 hours
Easy 3-digit time cycle setting
±0.1% repeatability
Timing light
Superior transient protection
Reinforced base locator pin
Flame-retardant polycarbonate housing
File #E59090
OUTPUT
Type: Relay DPDT (2 form C)
Rating: 10 A max. resistive at 240 VAC, 125 VDC
1/2 hp at 240 VAC; 10 mA at 5 VDC min. load
current
Life:
Mechanical: 10,000,000 operations
Full Load: 500,000 operations
ENVIRONMENTAL
Storage Temperature: -25°C to 70°C
Operating Temperature: -25°C to 55°C
Humidity: 95% relative
MECHANICAL
Termination: 11-pin plug or spade type
Mounting:
Back Panel Mounting:
Spade Base use MSO-00KUP-012
11-pin Base use MSO-0011P-012
Front Panel Mounting: 1.78” sq. opening required
Front Panel Mounting Bracket MBK-1/16D-011
11-pin Base use MSO-0011P-013
PROTECTION
Transient Voltage: 7 joule, 250 V metal oxide
varistor
Dielectric Breakdown: 1800 VAC, RMS min. at
60 Hz between input and outputs
TIMING LIGHT LOGIC
Repeat Cycle: Full On During OFF time
Flashing during ON time;
Other Logic Modes: Flashing during timing;
Full On after time out
TIMING
Selectable Time Ranges: .05 to 9.99 sec.; .1 to
99.9 sec.; 1 to 999 sec.; .1 to 99.9 minutes; 1 to
999 minutes; 1 to 999 hours (times less than 50
ms are not recommended due to the response
time of the mechanical relay)
Selectable Operating Logic Modes:
Repeat Cycle (50% fixed duty cycle)
Single Shot (1 shot)
Delay On Break (D.O.B.)
Interval (Intervl)
Delay On Make (D.O.M.)
PROGRAMMING
To program the timer, remove voltage from the
unit and select the operating logic mode and the
time range; use the digital switches to select the
required time (0 to 999)
ORDERING INFORMATION
0.05 sec. to 999 hrs.
0.05 sec. to 999 hrs.
TIME RANGE
TMM-9999M-96M
KMM-9999M-96M
PART NUMBER
TIME DELAY RELAYS
Spade (.187” x .020” terminal) type plug-in base
KMM PIN CONFIGURATION
KUP-SPADE SOCKET
PLUGS INTO
A
KMM-9999M-96M
1
4
A
50/60 Hz, 14 VA
7
24-240 VAC/DC
4
(44.6mm)
1
SQUARE
7
1.755
Input
MOUNTING TYPE
5
8
5
8
35 mm DIN rail
RANGE SELECT
"TIMING" LED
6
Start
Switch
3
9
(7.9mm)
3
6
9
9
9
9
.31
9
B
RANGE
9.99S
99.9S
9
. 9
9
9
9 S
9 M
9
9 H
LOGIC SELECT
B
M
(71.9mm)
SQUARE
(47.5mm)
TIME SELECT
SELECT
(94.5mm)
3.72 MAX.
2.830
1.870
TIME SELECT
FUNCTION
TMM PIN CONFIGURATION
5640
1-SHOT
REPEAT
D.O.B.
D.O.M.
SELECT
INTVL
11-PIN SOCKET
PLUGS INTO
2
50/60 Hz, 14VA
TMM-9999M-96M
24-240 VAC/DC
(44.6mm)
SQUARE
3
4
1.755
1
5
Input
6
6
(16.8mm)
.66
Start
Switch
7
11
1-3
8
9
10

Related parts for MSO-0011P-012