MSO-0011P-012 NCC, MSO-0011P-012 Datasheet - Page 42

no-image

MSO-0011P-012

Manufacturer Part Number
MSO-0011P-012
Description
Socket, Relay; 11 Pin Octal, ID# SR3P-06
Manufacturer
NCC
Type
Octalr
Datasheet

Specifications of MSO-0011P-012

Number Of Contacts
11
Time Range
0.05 Sec. to 999 Min.
Output Rating
10 A @ 240 VAC Max.; 100 mA @ 5 VDC Min.
Operating Temperature
–23°C to +55°C
1-32
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
Universal Voltage Input Buffer
ASY-INPUT-BUFR
FEATURES
The universal input buffer will take any volt-
age from 10.6 to 265 VAC/DC and actuate
any NCC timer requiring a start switch to
initiate a timing cycle.
Operating Logic: Upon application of input
voltage, the output becomes an effective
contact closure (within 50 ms). Upon remov-
al of input voltage, the output becomes an
effective open circuit (within 50 ms).
LOGIC FUNCTION DIAGRAM
Control
Input
Output
ORDERING INFORMATION
INPUT VOLTAGE RANGE
Universal control voltage range: 12 to
240 VAC/DC
Controls all NCC timers requiring start
switch input
No need for isolated start switch con-
tacts
Easy interface to programmable logic
controllers
Completely solid state, no moving parts
to wear out
Circuitry completely encapsulated
Low cost
Compact size
Superior transient protection
Flame-retardant and solvent-resistant
polyester thermoplastic housing
12 to 240 VAC/DC
On
Off
Closed
Open
TIME DELAY RELAYS
File #E164906
50 mSec.
max.
ASY-INPUT-BUFR
PART NUMBER
50 mSec.
max.
SPECIFICATIONS
INPUT
AC: 10.6 to 265 VAC 50/60 Hz, 5 mA max.
DC: 10.6 to 265 VDC 5 mA max.
Input-Output Delay: 50 ms max.
OUTPUT
Effective contact closure for NCC timers:
Closure: VAC = 9 to 265, 50/60 Hz (6 mA max.)
Closure: VDC = 9 to 265, (6 mA max.)
Voltage drop across output: 2.2 VAC/VDC max.
at I=6 ma
Output leakage: At Vin= 0 VDC and Vout = 265
VDC, leakage is 25 uA DC max.
PROTECTION
Transient Voltage: 30 joule metal oxide varistor
Dielectric breakdown: 3000 Vrms terminal to
mounting; 1500 Vrms input to output
Insulation resistance: 100 megohms min.
between terminals and case
MECHANICAL
Termination: .25” x .032” male fast-on terminals
Mounting: Surface mount with one #8 screw
ENVIRONMENTAL
Storage temperature: -40°C to 85°C
Operating temperature: -40°C to 65°C
Humidity: 95% relative max.
Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).
TIMER-TRIGGER
INPUT VOLTAGE SOURCE
(Typical Wiring Diagram)
.250 X .032 MALE
SPADE TERMINAL
(4 PLACES)
5
(TO START SW)
TO NCC
1
INPUTS
OUTPUT
12-240 VAC/DC
CONTROL INPUT
1.25
.885
4
National Controls
Corporation
West Chicago, IL.
60185
INPUT BUFFER
Model No.:
ASY-INPUT-BUFR
V
3
.170
DIA.

Related parts for MSO-0011P-012