EP1S80F1020C6 Altera, EP1S80F1020C6 Datasheet - Page 42

no-image

EP1S80F1020C6

Manufacturer Part Number
EP1S80F1020C6
Description
IC STRATIX FPGA 80K LE 1020-FBGA
Manufacturer
Altera
Series
Stratix®r
Datasheet

Specifications of EP1S80F1020C6

Number Of Logic Elements/cells
79040
Number Of Labs/clbs
7904
Total Ram Bits
7427520
Number Of I /o
773
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
1020-FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Other names
544-1439
EP1S80F1020C6

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1S80F1020C6
Manufacturer:
ALTERA
Quantity:
528
Part Number:
EP1S80F1020C6
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1S80F1020C6
Manufacturer:
ALTERA
Quantity:
6 000
Part Number:
EP1S80F1020C6
Manufacturer:
ALTERA
Quantity:
6 000
Part Number:
EP1S80F1020C6
Manufacturer:
ALTERA
0
Part Number:
EP1S80F1020C6
Manufacturer:
ALTERA
Quantity:
180
Part Number:
EP1S80F1020C6
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP1S80F1020C6
0
Part Number:
EP1S80F1020C6L
Manufacturer:
ALTERA
0
Part Number:
EP1S80F1020C6N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
TriMatrix Memory
2–28
Stratix Device Handbook, Volume 1
M512 RAM blocks can have different clocks on its inputs and outputs.
The wren, datain, and write address registers are all clocked together
from one of the two clocks feeding the block. The read address, rden, and
output registers can be clocked by either of the two clocks driving the
block. This allows the RAM block to operate in read/write or
input/output clock modes. Only the output register can be bypassed. The
eight labclk signals or local interconnect can drive the inclock,
outclock, wren, rden, inclr, and outclr signals. Because of the
advanced interconnect between the LAB and M512 RAM blocks, LEs can
also control the wren and rden signals and the RAM clock, clock enable,
and asynchronous clear signals.
control signal generation logic.
The RAM blocks within Stratix devices have local interconnects to allow
LEs and interconnects to drive into RAM blocks. The M512 RAM block
local interconnect is driven by the R4, R8, C4, C8, and direct link
interconnects from adjacent LABs. The M512 RAM blocks can
communicate with LABs on either the left or right side through these row
interconnects or with LAB columns on the left or right side with the
column interconnects. Up to 10 direct link input connections to the M512
RAM block are possible from the left adjacent LABs and another
10 possible from the right adjacent LAB. M512 RAM outputs can also
connect to left and right LABs through 10 direct link interconnects. The
M512 RAM block has equal opportunity for access and performance to
and from LABs on either its left or right side.
RAM block to logic array interface.
Figure 2–15
shows the M512 RAM block
Figure 2–16
Altera Corporation
shows the M512
July 2005