Specifications of EP1S10F780I6N

Number Of Logic Elements/cells
10570
Number Of Labs/clbs
1057
Total Ram Bits
920448
Number Of I /o
426
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
780-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1S10F780I6N
Manufacturer:
ALTERA
Quantity:
3 000
Part Number:
EP1S10F780I6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1S10F780I6N
Manufacturer:
ALTERA
0
Stratix & Stratix GX I/O Standards
4–6
Stratix Device Handbook, Volume 2
1.5-V Differential HSTL - EIA/JEDEC Standard EIA/JESD8-6
The differential HSTL I/O standard is used for applications designed to
operate in the 0.0- to 1.5-V HSTL logic switching range such as quad data
rate (QDR) memory clock interfaces. The differential HSTL specification
is the same as the single ended HSTL specification. The standard specifies
an input voltage range of – 0.3 V V
does not require an input reference voltage, however, it does require a
50
Figure
clock levels for 1.5-V differential HSTL. The input clock is implemented
using dedicated differential input buffer. Two single-ended output
buffers are automatically programmed to have opposite polarity so as to
implement a differential output clock.
Figure 4–3. 1.5-V Differential HSTL Class I Termination
3.3-V PCI Local Bus - PCI Special Interest Group PCI Local Bus
Specification Rev. 2.3
The PCI local bus specification is used for applications that interface to
the PCI local bus, which provides a processor-independent data path
between highly integrated peripheral controller components, peripheral
add-in boards, and processor/memory systems. The conventional PCI
specification revision 2.3 defines the PCI hardware environment
including the protocol, electrical, mechanical, and configuration
specifications for the PCI devices and expansion boards. This standard
requires 3.3-V V
with the 3.3-V PCI Local Bus Specification Revision 2.3 and meet
64-bit/66-MHz operating frequency and timing requirements. The 3.3-V
PCI standard does not require input reference voltages or board
terminations. Stratix and Stratix GX devices support both input and
output levels.
Transmitter
resistor termination resistor to V
Differential
4–3). Stratix and Stratix GX devices support both input and output
CCIO
. Stratix and Stratix GX devices are fully compliant
Z
Z
0
0
= 50 Ω
= 50 Ω
50 Ω
V
TT
I
= 0.75 V
TT
V
CCIO
at the input buffer (see
+ 0.3 V. Differential HSTL
50 Ω
V
TT
= 0.75 V
Altera Corporation
Differential
Receiver
June 2006

Related parts for EP1S10F780I6N