ADBM-A350-200 Avago Technologies US Inc., ADBM-A350-200 Datasheet - Page 18

no-image

ADBM-A350-200

Manufacturer Part Number
ADBM-A350-200
Description
Vigor Colossus OFN Module
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of ADBM-A350-200

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Data Packet (DP)
Contains 8 data bits and may be sent by the host or the ADBM-A350.
Host Driven Packets
The host initiates all data transmission with a START
condition. Next, slave address and register address
packets are sent. If there is a device address match, the
ADBM-A350 then responds to each Eight-bit data trans-
mission with an acknowledge signal (SDA = 0). Data is
transmitted with the most signifi cant bit fi rst.
Figure 15. Host packets
18
SCL driven
by host
First bit of
SDA
packet
DP[7]
Start
DP[6]
Module must respond after each
D7
data byte with a 1-bit 0-valued
7
Not acknowledging (NAK)
signals indicate an error
Host Driven
Packet
D6–D1
6 – 1
DP[5]
acknowledge (ACK)
condition
D0
DP[4]
0
Data
ADBS
Driven
ACK
ACK
DP[3]
D7
7
Host Driven
Packet
DP[2]
6 – 1
To terminate the transfer of host driven packets, the host
follows the ADBM-A350’s ACK with a STOP condition. The
host can also issue a START condition after the ADBM-
A350’s ACK if it wants to start a new data transfer.
transmission by following
Host terminates data
condition or another
the ACK with a STOP
START condition
DP[1]
D0
0
ADBS
Driven
ACK
ACK
Last bit of
DP[0]
packet
STOP or
START
Condition
Host
Driven

Related parts for ADBM-A350-200