IC AFE POLYPHASE MULTI 28-TSSOP

MAXQ3180-RAN+

Manufacturer Part Number
MAXQ3180-RAN+
Description
IC AFE POLYPHASE MULTI 28-TSSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAXQ3180-RAN+

Number Of Channels
8
Power (watts)
35mW
Voltage - Supply, Analog
3.6V
Voltage - Supply, Digital
3.6V
Package / Case
28-TSSOP
For Use With
MAXQ3180-KIT - KIT EV REFRNC DSIGN FOR MAXQ3180
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Bits
-
Bit:
Name:
Reset:
BIT
2:1
7
6
5
4
3
LINFRM
WIRSYS
DHARA
DFUNA
NAME
DFUN
Low-Power, Multifunction, Polyphase AFE
______________________________________________________________________________________
7
0
Reserved.
When set, disables automatic determination of the filter parameters for the harmonic filter coefficient. If
set by the host software, the host must set a value in the A1HARM filter coefficient register to
establish the operating frequency of this filter if harmonic-mode calculations are used. When cleared,
the MAXQ3180 automatically determines the value of the harmonic-filter coefficient based on the
measured line frequency and the harmonic-order requested (AUX_CFG.ORDH).
When set, disables automatic determination of the filter parameters for the fundamental-mode filter
described above. If set by the host software, the host must set a value in the A1FUND filter coefficient
register to establish the operating frequency of this filter if fundamental-mode calculations are used.
When clear, the MAXQ3180 automatically determines the value of the fundamental-mode filter
coefficient based on the measured line frequency.
When set, fundamental-mode calculations are disabled. Fundamental-mode calculations provide
information about power and energy that are consumed only at the fundamental line frequency apart
from any harmonics that could be present. Setting this bit disables all fundamental frequency registers
but allows the MAXQ3180 to calculate other parameters at a higher rate. Set this bit when (1)
fundamental mode values do not need to be read, and (2) R_ADCRATE needs to be reduced below its
default value.
Selects the current linearity offset calibration method. See the Calibrating Current Offset section for
more information.
0 = IRMS
1 = IRMS + OFFS
These bits select the coefficient used in calculating apparent power.
00 = 1-phase, 3-wire (1P3W), or 3-phase, 4-wire (3P4W) (C = 1)
01 = 3-phase, 3-wire (3P3W) (C = 3/2)
10 = three voltages, three currents (3V3A) (C = 3/3)
3P3W Wiring (01)
DHARA
6
0
2
+ OFFS
DFUNA
5
0
DFUN
Operating Mode Register 2 (OPMODE2) (0x003)
0
4
FUNCTION
LINFRM
3
0
V
AB
2
0
V
WIRSYS
CB
I
A
I
C
1
0
APPSEL
0
0
31