ADF4107BRUZ Analog Devices Inc, ADF4107BRUZ Datasheet - Page 17

no-image

ADF4107BRUZ

Manufacturer Part Number
ADF4107BRUZ
Description
IC SYNTH FREQ PLL 7GHZ 16-TSSOP
Manufacturer
Analog Devices Inc
Type
Clock/Frequency Synthesizer (RF)r
Datasheet

Specifications of ADF4107BRUZ

Pll
Yes
Input
CMOS
Output
Clock
Number Of Circuits
1
Ratio - Input:output
2:1
Differential - Input:output
Yes/No
Frequency - Max
7GHz
Divider/multiplier
No/No
Voltage - Supply
2.7 V ~ 3.3 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
16-TSSOP
Frequency-max
7GHz
Pll Type
Frequency Synthesis
Frequency
7GHz
Supply Current
15mA
Supply Voltage Range
2.7V To 3.3V
Digital Ic Case Style
TSSOP
No. Of Pins
16
Operating Temperature Range
-40°C To +85°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADF4107BRUZ
Manufacturer:
AD
Quantity:
2 200
Part Number:
ADF4107BRUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADF4107BRUZ-REEL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Charge Pump Currents
CPI3, CPI2, and CPI1 program Current Setting 1 for the charge
pump. CPI6, CPI5, and CPI4 program Current Setting 2 for the
charge pump. The truth table is given in Figure 25.
Prescaler Value
P2 and P1 in the function latch set the prescaler values. The
prescaler value should be chosen so that the prescaler output
frequency is always less than or equal to 300 MHz. Thus, with
an RF frequency of 4 GHz, a prescaler value of 16/17 is valid but
a value of 8/9 is not valid.
PD Polarity
This bit sets the phase detector polarity bit. See Figure 25.
CP Three-State
This bit controls the CP output pin. With the bit set high, the
CP output is put into three-state. With the bit set low, the CP
output is enabled.
INITIALIZATION LATCH
The initialization latch is programmed when C2 and C1 are set
to 1 and 1. This is essentially the same as the function latch
(programmed when C2, C1 = 1, 0).
However, when the initialization latch is programmed an
additional internal reset pulse is applied to the R and AB
counters. This pulse ensures that the AB counter is at load point
when the AB counter data is latched and the device will begin
counting in close phase alignment.
If the latch is programmed for synchronous power-down (CE
pin is high; PD1 bit is high; PD2 bit is low), the internal pulse
also triggers this power-down. The prescaler reference and the
oscillator input buffer are unaffected by the internal reset pulse and
so close phase alignment is maintained when counting resumes.
When the first AB counter data is latched after initialization, the
internal reset pulse is again activated. However, successive AB
counter loads after this will not trigger the internal reset pulse.
DEVICE PROGRAMMING AFTER INITIAL POWER-UP
After initially powering up the device, there are three ways to
program the device.
Initialization Latch Method
1.
2.
3.
4.
Apply V
Program the initialization latch (11 in two LSBs of input
word). Make sure that the F1 bit is programmed to 0.
Next, do a function latch load (10 in two LSBs of the
control word), making sure that the F1 bit is programmed
to a 0.
Then do an R load (00 in two LSBs).
DD
.
Rev. A | Page 17 of 20
5.
6.
a.
b.
c.
CE Pin Method
1.
2.
3.
4.
5.
6.
Note that after CE goes high, a duration of 1 μs may be required
for the prescaler band gap voltage and oscillator input buffer
bias to reach steady state.
CE can be used to power the device up and down in order to
check for channel activity. The input register does not need to
be reprogrammed each time the device is disabled and enabled
as long as it has been programmed at least once after V
initially applied.
Counter Reset Method
1.
2.
3.
4.
5.
This sequence provides the same close alignment as the
initialization method. It offers direct control over the internal
reset. Note that counter reset holds the counters at load point
and three-states the charge pump, but does not trigger
synchronous power-down.
Then do an AB load (01 in two LSBs).
When the initialization latch is loaded, the following
occurs:
The function latch contents are loaded.
An internal pulse resets the R, AB, and timeout counters to
load-state conditions and also three-states the charge
pump. Note that the prescaler band gap reference and the
oscillator input buffer are unaffected by the internal reset
pulse, allowing close phase alignment when counting
resumes.
Latching the first AB counter data after the initialization
word activates the same internal reset pulse. Successive AB
loads do not trigger the internal reset pulse unless there is
another initialization.
Apply V
Bring CE low to put the device into power-down. This is
an asychronous power-down in that it happens immediately.
Program the function latch (10).
Program the R counter latch (00).
Program the AB counter latch (01).
Bring CE high to take the device out of power-down. The
R and AB counters resume counting in close alignment.
Apply V
Do a function latch load (10 in two LSBs). As part of this,
load 1 to the F1 bit. This enables the counter reset.
Do an R counter load (00 in two LSBs).
Do an AB counter load (01 in two LSBs).
Do a function latch load (10 in two LSBs). As part of this,
load 0 to the F1 bit. This disables the counter reset.
DD
DD
.
.
ADF4107
DD
was

Related parts for ADF4107BRUZ