8.2.3 Turn On No Load Operation
At power on the system shall present a no load condition to the power supply. In this no load
state the voltage regulation limits for the 3.3V and 5V are relaxed to +/-10% and the +12V rails
relaxed to +10/-8%. When operating loads are applied the voltages must regulated to there
normal limits.
Notes:
38
1.
2.
3.
4.
5.
6.
1.
2.
3.
4.
Combined 3.3 V and 5 V power shall not exceed 100 W.
Maximum continuous total DC output power should not exceed 400 W.
Peak load on the combined 12 V output shall not exceed 49 A.
Maximum continuous load on the combined 12 V output shall not exceed 44 A.
Peak total DC output power should not exceed 650 W.
Peak power and current loading shall be supported for a minimum of 12 seconds.
Maximum continuous total DC output power should not exceed 400 W.
Peak load on the combined 12 V output shall not exceed 49 A.
Maximum continuous load on the combined 12 V output shall not exceed 44 A.
Peak total DC output power should not exceed 650 W.
+3.3 V
+5 V
+12 V
+12 V
+12 V
+12 V
-12 V
+5 VSB
+3.3 V
+5 V
+12 V
+12 V
+12 V
+12 V
-12 V
+5 VSB
Voltage
Voltage
1
2
3
4
5
1
2
3
4
1
1.5 A
1.0 A
0.5 A
0.5 A
0.5 A
0.5 A
0 A
0.1 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0.1 A
Minimum Continuous
Minimum Continuous
Intel order number: D64569-006
Table 31. 400W Load Ratings
Table 32. No-load Operating Range
10 A
20 A
16 A
16 A
16 A
16 A
0.5 A
3.0 A
7 A
5 A
5 A
5 A
6 A
5 A
0.5 A
3.0 A
Maximum Continuous
Maximum Continuous
Intel
®
Server Board S5000VCL TPS
18 A
18 A
3.5 A
7 A
7 A
3.5 A
Peak
Peak
Revision 2.2