SR1530HCLR Intel (CPU), SR1530HCLR Datasheet - Page 40

no-image

SR1530HCLR

Manufacturer Part Number
SR1530HCLR
Description
Manufacturer
Intel (CPU)
Datasheet

Specifications of SR1530HCLR

Lead Free Status / RoHS Status
Not Compliant
Jumper Block Settings
6.1.2
When performing a standard BMC firmware update procedure, the update utility places the
BMC into an update mode, allowing the firmware to load safely onto the flash device. In the
unlikely event that the BMC firmware update process fails due to the BMC not being in the
proper update state, the server board provides a BMC Force Update jumper which will force the
BMC into the proper update state. The following procedure should be following in the event the
standard BMC firmware update process fails.
Note: Normal BMC functionality is disabled with the Force BMC Update jumper set to the
“Enabled” position. The server should never be run with the BMC Force Update jumper set in
this position and should only be used when the standard firmware update process fails. This
jumper should remain in the Default – Disabled position when the server is running normally.
6.2
The jumper block located at J3A2, is used to select which BIOS image the system will boot to.
Pin 1 on the jumper is identified by ‘▼’. This jumper should only be moved to force the BIOS to
boot to the secondary bank, which may hold a different version of BIOS.
The rolling BIOS feature of the server board will automatically alternate the Boot BIOS to the
secondary bank if the BIOS image in the primary bank is corrupted and cannot boot.
30
1. Power down and remove AC power.
2. Open the server.
3. Move jumper from the Default operating position (pins1-2) to the Enabled position (pins
4. Close the server chassis.
5. Reconnect AC and power up the server.
6. Perform the BMC firmware update procedure that is documented in README.TXT file
7. After successful completion of the firmware update process, the firmware update utility
8. Power down and remove the AC power.
9. Open the server.
10. Move the jumper from the Enabled position (pins 2-3) to the Disabled position (pins 1-2).
11. Close the server chassis.
12. Reconnect AC and power up the server.
2-3).
that is included in the given BMC Firmware Update package.
may generate an error stating that the BMC is still in update mode.
BIOS Select Jumper
BMC Force Update Procedure
Intel order number: D64569-006
Intel
®
Server Board S5000VCL TPS
Revision 2.2