Intel
When the AC power is first applied to the system and 5-volt standby is present, the BMC on the
server board requires 15-20 seconds to initialize. During this time, the system status LED blinks
amber and green, and the power button functionality is disabled, preventing the server from
powering up. Once BMC initialization has completed, the status LED will stop blinking and the
power button functionality is restored and can be used to turn on the server.
The bi-color 5V Standby System Status LED operates as follows:
Revision 2.2
Color
®
Server Board S5000VCL TPS
N/A
Alternating
Blink
Solid on
Blink
Blink
Solid on
State
Not ready
Not ready
System OK
Degraded
Non-critical
Critical, non-
recoverable
Criticality
Intel order number: D64569-006
AC power off
Pre-DC power on – 15-20 second BMC initialization when AC is
applied to the server. Control Panel buttons are disabled until the
BMC initialization is complete.
System booted and ready.
System degraded
Non-fatal alarm – system is likely to fail
Fatal alarm – system has failed or shutdown
Unable to use all of the installed memory (more than one DIMM
installed).
Correctable errors over a threshold of 10 and migrating to a
spare DIMM (memory sparing). This indicates that the user no
longer has spared DIMMs indicating a redundancy lost
condition. Corresponding DIMM LED should light up.
In mirrored configuration, when memory mirroring takes place
and system loses memory redundancy. This is not covered by
the bullet above.
Redundancy loss such as power-supply or fan. This does not
apply to non-redundant sub-systems.
PCI-e link errors
CPU failure / disabled – if there are two processors and one of
them fails
Fan alarm – Fan failure. Number of operational fans should be
more than minimum number needed to cool the system
Non-critical threshold crossed – Temperature and voltage
Critical voltage threshold crossed
VRD hot asserted
Minimum number of fans to cool the system not present or failed
In non-sparing and non-mirroring mode if the threshold of ten
correctable errors is crossed within the window
DIMM failure when there is one DIMM present, no good memory
present
Run-time memory uncorrectable error in non-redundant mode
IERR signal asserted
Processor 1 missing
Temperature (CPU ThermTrip, memory TempHi, critical
threshold crossed)
No power good – power fault
Processor configuration error (for instance, processor stepping
mismatch)
Description
Intel® Light Guided Diagnostics
33