IDT77V126L200TFI IDT, Integrated Device Technology Inc, IDT77V126L200TFI Datasheet - Page 15

no-image

IDT77V126L200TFI

Manufacturer Part Number
IDT77V126L200TFI
Description
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of IDT77V126L200TFI

Number Of Channels
1
Type Of Atm Phy Interface
UTOPIA
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
3V
Operating Supply Voltage (max)
3.6V
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Pin Count
64
Mounting
Surface Mount
Lead Free Status / RoHS Status
Not Compliant
Counters
that these counters will be polled from time to time (user selectable) to evaluate performance.
Error counter and HEC Error counter were given sufficient size to indicate exact counts for low error-rate conditions. If these counters overflow, a
gross condition is occurring, where additional counter resolution does not provide additional diagnostic benefit.
Loop Timing Feature
the loop timing mode is enabled in the Enhanced Control Register 1 bit 6, the recovered receive clock is used as to clock out data on transmit side. In
normal mode, the transmitter transmits data using the multiplied oscillator clock.
jitter measured at various data rates. The set-up shown in Figure 15 was used to perform these tests. The maximum jitter seen was at TX point 5 and
the minimum jitter was at point 2. The loop timing jitter is defined as the amount of jitter generated by each TX node. In other words, the loop timing
jitter or the jitter added by a loop-timed port in the set-up below is the difference between the Total Output Jitter and the Total Input Jitter.
IDT77V126L200
Several condition counters are provided to assist external systems (e.g. software drivers) in evaluating communications conditions. It is anticipated
The TxCell and RxCell counters are sized (16 bits) to provide a full cell count (without roll over) if the counter is read once/second. The Symbol
Reading Counters
1. Decide which counter value is desired. Write to the Counter Select Register to the bit location corresponding to the desired counter. This loads
2. Read the Counter Registers (low byte and high byte) to get the value.
Further reads may be accomplished in the same manner by writing to the Counter Select Registers.
The 77v126 also offers a loop timing feature for specific applications where data needs to be repeated / transmitted using the recovered clock. If
Jitter in Loop Timing Mode
One of the primary concerns when using loop timing mode is the amount of jitter that gets added each time data is transmitted. Table 3 shows the
!
!
!
!
– 8 bits
– counts all invalid 5-bit symbols received
– 16 bits
– counts all transmitted cells
– 16 bits
– counts all received cells, excluding idle cells and HEC errored cells
– 5 bits
– counts all HEC errors received
the High and Low Byte Counter Registers with the selected counter’s value, and resets this counter to zero.
Symbol Error Counters
Transmit Cell Counters
Receive Cell Counters
Receive HEC Error Counters
Note: Only one counter may be enabled at any time in each of the Counter Select Registers.
Note: The PHY takes some time to set up the low and high byte counters after a specific counter has been selected in the Counter Selector
register. This time delay (in µ S) varies with the line rate and can be calculated as follows:
Time delay (µ S) =
line rate (Mbps)
12.5___
15 of 30
December 2004