TL1550EXT Fluke, TL1550EXT Datasheet - Page 4

no-image

TL1550EXT

Manufacturer Part Number
TL1550EXT
Description
TEST LEADS
Manufacturer
Fluke
Datasheet

Specifications of TL1550EXT

Cable Length
25ft
Lead Length
25ft
Display Type
Component Test Equipment and Logic Probes
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
4
Documenting
Process Calibrators
744 upgrades available
Fluke periodically releases
new internal software for the
Fluke 744. These upgrades
include:
For details of the
latest upgrade, see
www.fluke.com/744upgrade
New revisions of previously
supported instruments.
Device-specific command
support for new instruments.
New HART communication
capability.
For more detailed information, go to www.fluke.com/744
Versatile HART protocol support (744 only)
744 Documenting Process Calibrator.
Communicate, calibrate and configure HART instrumentation
The Fluke 744 offers the ability to perform every day calibration, maintenance,
and troubleshooting of HART
With one powerful tool, you can:
The 744 supports these classes of
instructions:
Recommended accessories – 741B, 743B and 744 calibrators
Monitor, control and calibrate HART
instrumentation with integrated
communication functions.
Generate precision electrical, tem-
perature or pressure signals for
analog stimulus or sensor simulation.
Simultaneously measure electrical,
temperature or pressure signals from
transmitter output.
Interrogate HART devices to deter-
mine type, manufacturer, model and
tag-ID.
Read HART PV, smart transmitter
digital output.
Universal commands — such as “read
manufacturer and device type,” “read
primary variable (PV),” or “read cur-
rent output and percent of span”
Accessory Case
See page 42
Meter and
C789
Temperature
See page 40
Pipe Clamp
80PK-8
®
instrumentation with just one tool.
Pressure Modules
Fluke-700Pxx
See page 7
Make field adjustments to ranging,
damping and other top-level config-
uration settings.
Change/assign the tag of HART
transmitter smart transmitters.
Re-configure HART temperature
sensor (e.g., TC to RTD).
Perform HART sensor trim and output
trim.
Perform loop test with simultaneous
analog and digital mA readout.
Control selected Hart Scientific Dry
Blocks.
Common practice commands — such
as “read multiple variables,” “set
damping time,” or “loop test”
Device-specific commands —
functions unique to a particular field
device, like “sensor trim” or output
trim
Temperature Probe
SureGrip Piercing
Pressure
Enabled
80PK-25
SureGrip Industrial
Test Lead Set
TL220