TL1550EXT Fluke, TL1550EXT Datasheet - Page 27

no-image

TL1550EXT

Manufacturer Part Number
TL1550EXT
Description
TEST LEADS
Manufacturer
Fluke
Datasheet

Specifications of TL1550EXT

Cable Length
25ft
Lead Length
25ft
Display Type
Component Test Equipment and Logic Probes
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
Summary specifications for 9132 and 9133
Hart Scientific 9132 and 9133
Infrared Calibrators
Precision when you need it for infrared
temperature calibration
Whether you’re using in-line
or handheld pyrometers, the
9132 Portable IR Calibrator
can handle your workload to
500 °C (932 °F). For calibrat-
ing IR guns at cold tempera-
tures, the 9133 Portable IR
Calibrator reaches –30 °C
(22 °F) in normal ambient
conditions.
check your IR guns. For higher
precision, a well is located
directly behind the blackbody
Temperature range
Accuracy
Stability
Target size
Target emissivity
Resolution
Heating time
Cooling time
Power
Size
Weight
Computer interface
NIST-traceable
contact calibration
Infrared
Calibrators
Simply “point and shoot” to
9132
50 °C to 500 °C
(122 °F to 932 °F)
± 0.5 °C at 100 °C
± 0.8 °C at 500 °C
± 0.1 °C at 100 °C
± 0.3 °C at 500 °C
2.25 in (57 mm)
0.95 (± 0.02 from 8 to 14 mm)
0.1 °
30 minutes (50 °C to 500 °C)
30 minutes (500 °C to 100 °C)
115 VAC (± 10 %), 3 A or
230 VAC (± 10 %), 1.5 A,
switchable, 50/60 Hz, 340 W
4 H x 6 W x 7 D in
(102 x 152 x 178 mm)
4 lb. (1.8 kg)
RS-232 included with free Interface-it software
Data at 50 °C, 100 °C, 200 °C,
250 °C, 300 °C, 400 °C
and 500 °C
surface for contact calibration
of the blackbody using a cali-
brated PRT and readout. The
2.25 in (57 mm) target offers a
large field of view area for
optical variations in infrared
thermometers. Emissivity of
the target is 0.95 (± 0.02) and
its temperature may be con-
trolled in increments of 0.1 °C.
this performance in a compact
package!
No other IR calibrators offer
9133
–30 °C to 150 °C at 23 °C ambient
(–22 °F to 302 °F at 73 °F ambient)
± 0.4 °C
± 0.1 °C
15 minutes (25 °C to 150 °C)
15 minutes (25 °C to –20 °C)
115 VAC (± 10 %), 1.5 A, or
230 VAC (± 10 %), 1.0 A,
switchable, 50/60 Hz, 200 W
6 H x 11.25 W x 10.5 D in
(152 x 286 x 267 mm)
10 lb. (4.6 kg)
Data at –30 °C, 0 °C, 25 °C, 75 °C,
100 °C, 125 °C and 150 °C
Ordering information
9132-156
50/60 Hz
9132-256 IR
50/60 Hz
9133-156 IR
50/60 Hz
9133-256 IR
50/60 Hz
9308
(9132)
9302
(9133)
Hard Carrying Case
Hard Carrying Case
IR Calibrator, 110 V
Hart Scientific
Calibrator, 110 V
Calibrator, 220 V
Calibrator, 220 V
27