TL1550EXT Fluke, TL1550EXT Datasheet - Page 11

no-image

TL1550EXT

Manufacturer Part Number
TL1550EXT
Description
TEST LEADS
Manufacturer
Fluke
Datasheet

Specifications of TL1550EXT

Cable Length
25ft
Lead Length
25ft
Display Type
Component Test Equipment and Logic Probes
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
789 and 787 specifications (18 °C to 28 °C, one year)
Temperature range of 18 °C to 28 °C, for one year after calibration
Maximum voltage applied
between any jack and earth ground:
1000 V rms
Storage temperature: -40 °C to 60 °C
Operating temperature: -20 °C to 55 °C
Temperature coefficient:
0.05 x (specified accuracy) per °C (for
temperatures < 18 °C or > 28 °C)
Relative humidity:
95 % up to 30 °C; 75 % up to 40 °C;
45 % up to 50 °C; 35 % up to 55 °C
Vibration: Random, 2 g, 5-500 Hz
General specifications for the Fluke 789 and 787 ProcessMeter Test Tools
Measurement function
V dc
V ac (true-rms) to 500 Hz
mA dc
A dc
A ac
Resistance
Frequency
(0.5 Hz to 20 kHz)
Diode Test
Continuity
Output function
DC current output
(internal battery operation)
DC current simulate
(ext. 24 Volt loop supply)
24 V loop supply
Current adjustment modes
Best accuracy
range and resolution
400.0 mV, 4.000 V, 40.00 V,
400.0 V, 1000 V
400.0 mV, 4.000 V, 40.00 V,
400.0 V, 1000 V
30.000 mA
1.000 A (0.440 A continuous)
1.000 A (0.440 A continuous)
400.0 Ohms, 4.000 k, 40.00 k,
400.0 k, 4.0 M, 40 M
199.99 Hz, 1999.9 Hz, 19.999 kHz
789: 2.000 V (shows diode voltage drop)
787: 2.400 V (shows diode voltage drop)
Beeps for resistance < approx. 100 ohms
Range and resolution
0.000 to 20.000 mA or
4.000 to 20.000 mA
(selectable at power-up)
Over-range to 24.000 mA
0.000 to 20.000 mA or 4.000 to 20.000 mA,
(selectable at power-up)
Over-range to 24.000 mA
789: Minimum 24 V
787: not available
Manual: Coarse, Fine, 25 % step (100 % step in 789)
Automatic: Slow Ramp, Fast Ramp, 25 % step
Shock: One meter drop test
Safety (789 and 787): Designed in
accordance with EN61010-1, ANSI/ISA
S82.01-1994 and CAN/CSA C22.2 No.
1010..1-92 Over-voltage Category III
Size/weight (789): 50 mm H x 100 mm
W x 203 mm L (1.97 in H x 3.94 in W x
8.00 in L), 600 g (1.3 lbs)
Size/weight (787 with holster and test
lead storage): 52 mm H x 98 mm W x
201 mm L (2.06 in H x 3.86 in W x
7.93 in L), 22.5 oz
(% of reading + LSD)
0.1 % + 1
0.7 % + 2
.05 % + 2
0.2 % + 2
1 % + 2
0.2 % + 1
.005 % +1
2 % + 1
Drive
capability
789: 24 V compliance
or, 1200 Ω @ 20 mA
787: 12 V compliance
or, 500 Ω @ 24 mA
789: 15 V to 48 V
787: 15 V to 30 V
≥ 24 V @ 24 mA,
1200 Ω (789 only)
Battery (787): Single 9 V alkaline
battery
Battery life (787): 12 to 50 hours
typical
Battery (789): Four AA alkaline
batteries
Battery life (789): 14 to 140 hours
typical
Warranty: Three years
Accuracy
(% of span)
.05 %
.05 %
11