DV3100 DIGIVIEW, DV3100 Datasheet - Page 57

no-image

DV3100

Manufacturer Part Number
DV3100
Description
LOGIC ANALYSER, DIGITAL, 100MHZ, 18CH
Manufacturer
DIGIVIEW
Datasheet

Specifications of DV3100

No. Of Data Channels
18
No. Of Clock Inputs
8
Frequency
100MHz
Power Consumption
2.5W
External Height
0.75"
External Width
2.8"
External Depth
4.75"
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Capturing Data
53
Symptom
Causes & Solutions
REMEDY: Edit the signal definition and
change the channel selection. The colors are
repeated for each group of 9 channels, so be
sure to select the correct one.
(C). The signal definition has been "disabled".
REMEDY: Edit the signal definition and
uncheck the Disabled option. The channels for
disabled signals will not appear in the
captured data.
(D). Bad Ground reference.
REMEDY: Connect one of DigiView's ground
wires (black probes) to a ground point as
electrically close as possible to the signal
connections.
(E). Incorrect Trigger Threshold.
REMEDY: The transitions will be
undetectable If the trigger threshold is set too
high or too low for the voltage range of the
transitioning signal. Change the Threshold
setting for the physical channel so that it is
near the center of the signal's voltage swing.
(F). Insufficient power, see 1.B above.
© 2010 TechTools