DV3100 DIGIVIEW, DV3100 Datasheet - Page 29

no-image

DV3100

Manufacturer Part Number
DV3100
Description
LOGIC ANALYSER, DIGITAL, 100MHZ, 18CH
Manufacturer
DIGIVIEW
Datasheet

Specifications of DV3100

No. Of Data Channels
18
No. Of Clock Inputs
8
Frequency
100MHz
Power Consumption
2.5W
External Height
0.75"
External Width
2.8"
External Depth
4.75"
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Configuration
25
2.3.2.1
Trigger Configuration
The new Trigger Configuration Screen introduces a dual-mode (GUI and text), schematic-like
approach to configuring the matches, sequencers and trigger output from a single window. A text
window shows the 'formula' for the configuration while the 'schematic' shows the flow. These two
sections update together to provide two distinct views of the configuration. Multiple trigger
configurations can also be selected and created using the selection area in the upper left corner of
this screen.
Trigger Configuration Selection
Multiple trigger configurations can be created and stored in the DigiView Data File. Use the
selection box to quickly chose another trigger
configuration. After making a selection, click the "apply" button on the bottom of the screen for the
changes to take affect. To create, copy or rename a configuration, use the icon to the left of the
selection box to open the
Trigger Selection
Editor.
© 2010 TechTools