DV3100 DIGIVIEW, DV3100 Datasheet - Page 46

no-image

DV3100

Manufacturer Part Number
DV3100
Description
LOGIC ANALYSER, DIGITAL, 100MHZ, 18CH
Manufacturer
DIGIVIEW
Datasheet

Specifications of DV3100

No. Of Data Channels
18
No. Of Clock Inputs
8
Frequency
100MHz
Power Consumption
2.5W
External Height
0.75"
External Width
2.8"
External Depth
4.75"
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
2.3.2.1.2 Sequencer
2.3.2.1.3 Trigger Selection Editor
42
DigiView User's Guide
The trigger circuit of the DV3xxx series includes 4 cascadable, 4 stage sequencers. These can be
chained in any combination to produce longer sequences ( 1@ 16 stages, 2 @ 8 stages...) Each
stage includes a 20 bit pass counter.
Setting the Counter
Double-Click in the counter to edit its value. When finished editing, either use the "Enter" or "Tab"
key to assign the new value to the configuration. Anytime the configuration changes, use the
"APPLY" button to activate the new settings.
NOTE: "0" is an invalid value, so the counter editor will enforce a minimum count of "1".
From this window, trigger configurations can be created, deleted, renamed and copied.
© 2010 TechTools