DS33R11 Maxim Integrated Products, DS33R11 Datasheet - Page 213

no-image

DS33R11

Manufacturer Part Number
DS33R11
Description
Network Controller & Processor ICs Ethernet Mapper with Integrated T1-E1-J1
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS33R11

Product
Framer
Number Of Transceivers
1
Supply Voltage (max)
1.89 V, 3.465 V
Supply Voltage (min)
1.71 V, 3.135 V
Supply Current (max)
100 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
BGA

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS33R11
Manufacturer:
DS
Quantity:
15
Part Number:
DS33R11
Manufacturer:
NSC
Quantity:
2 877
Part Number:
DS33R11
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS33R11
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS33R11+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS33R11+
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS33R11+CJ2
Manufacturer:
Maxim Integrated
Quantity:
10 000
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Bit 7: BERT Real-Time Synchronization Status (BSYNC). Real-time status of the synchronizer (this bit is not
latched). This bit is set when the incoming pattern matches for 32 consecutive bit positions. It is cleared when six
or more bits out of 64 are received in error. Refer to BSYNC in the BERT status register, TR.SR9, for an interrupt-
generating version of this signal.
Bit 6: BOC Detected (BD). A real-time bit that is set high when the BOC detector is presently seeing a valid
sequence and set low when no BOC is currently being detected.
Bit 5: Transmit Current-Limit Exceeded (TCLE). A real-time bit that is set when the 50mA (RMS) current limiter
is activated, whether the current limiter is enabled or not.
Bit 4: Transmit Open-Circuit Detect (TOCD). A real-time bit that is set when the device detects that the TTIP and
TRING outputs are open-circuited.
Bits 0 – 3: Receive Level Bits (RL0 to RL3). Real-time bits
NOTE: RL0 through RL3 only indicate the signal range as specified by the EGL bit in TR.LIC1. Example; if EGL =
1 and in T1 mode, RL0 through RL3 will only indicate a signal range of >-2.5dB to –15dB even if the signal is < -
15dB.
RL3
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
BSYNC
7
0
RL2
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
TR.INFO2
Information Register 2
11h
BD
6
0
RL1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
TCLE
5
0
RL0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
213 of 344
Receive Level (dB)
TOCD
Greater than -2.5
Less than -37.5
0
4
-10.0 to -12.5
-12.5 to -15.0
-15.0 to -17.5
-17.5 to -20.0
-20.0 to -22.5
-22.5 to -25.0
-25.0 to -27.5
-27.5 to -30.0
-30.0 to -32.5
-32.5 to -35.0
-35.0 to -37.5
-7.5 to -10.0
-2.5 to -5.0
-5.0 to -7.5
RL3
3
0
RL2
2
0
RL1
1
0
RL0
0
0

Related parts for DS33R11