C200HW-PD025 Omron, C200HW-PD025 Datasheet - Page 3

no-image

C200HW-PD025

Manufacturer Part Number
C200HW-PD025
Description
Power Supply
Manufacturer
Omron
Datasheet

Specifications of C200HW-PD025

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Use the improved SYSMAC CS1 PLCs to
scale advanced systems to the optimum size.
F-4
1
1
Wide Lineup Makes It Easy to Build the Optimum System
A total of nine CPU Unit models provide for
a wide range of applications, from
small-scale systems to large. The lineup
also includes Memory Cards, Serial
Two Series of Expansion Racks Up to 50 m Long for
Long-distance Expansion with Up to 72 Units and 7 Racks
With an expansion capacity
of up to 80 Units and 7
Racks over a distance of
12 meters, the CS1 can
meet large-scale control
needs. Alternatively, an I/O
Control Unit and I/O
Interface Units can be used
to connect two series of CS1
Longdistance Expansion
Racks extending up to 50
m each and containing a
total of up to 72 Units and 7
Racks. CS1 Basic I/O Units,
CS1 Special I/O Units, and
CS1 CPU Bus Units can be
mounted anywhere on the
Racks and programmed
without being concerned
about special remote
programming requirements.
Note: C200H Units cannot be
Program
Capacity
Product lineup
250 K
steps
120 K
steps
60 K
steps
30 K
steps
20 K
steps
10 K
steps
mounted on the Longdistance
Expansion Racks.
(LD: 0.04 µs,
(LD: 0.04 µs,
(Example: LD instruction processing speed,
960 pts
DM: 64
DM: 64
50 m
Kwords)
Kwords)
(LD: 0.04 µs,
(LD: 0.02 µs,
I/O Control Unit
9 Units
1,280 pts
DM: 64
DM: 128
Communications Boards, and a wide
selection of Special I/O Units that can be
used with any CPU Units to flexibly build the
system that meets the requirements.
Kwords)
Kwords)
DM
capacity)
CPU
(LD: 0.02 µs,
(LD: 0.02 µs,
(LD: 0.04 µs,
(LD: 0.02 µs,
(LD: 0.02 µs,
5,120 pts
2 Series of
Expansion Racks;
Up to 7 Racks Total
I/O Interface Unit
DM: 448
DM: 256
DM: 128
DM: 64
DM: 64
Terminating Resistor
Kwords)
Kwords)
Kwords)
Kwords)
Kwords)
Number of
I/O points
50 m
Control Up to 960 Points with
Units Mounted to the CPU Rack
The CS1 provides a high level of space
efficiency. As many as 960 I/O points can
be controlled by simply mounting ten Basic
I/O Units, with 96 I/O points each, to the
CPU Rack. Alternatively, as many as 80
analog I/O points can be used by mounting
five Analog Input Units and five Analog
Output Units.
Large Capacity CPU Units for
Greater Component Control Power
The CS1 CPU Units boast amazing capacity
with up to 5,120 I/O points, 250 Ksteps of
programming, 448 Kwords of data memory
(including expanded data memory) and
4,096 timers/counters each. With a large
programming capacity, CS1 PLCs are not
only ideal for large-scale systems but easily
handle value-added applications and other
advanced data processing.
System Bus Baud Rate Doubled
The data transfer rate between the CPU
Unit and certain Units has been doubled to
further improve total system performance.
Units of 8 points each
Five Analog Output
Special I/O Unit
Ten I/O Units of 96 points each
doubled
Baud rate
System bus
Five Analog Input Units
of 8 points each
CPU Unit
Improved Refresh Performance for Data Links,
Remote I/O Communications, and Protocol Macros
In the past, I/O refresh processing with the
CPU Bus Unit only occurred during I/O
refresh after instructions were executed.
With the new CS1, however, I/O can be
refreshed immediately by using the DLNK
instruction. Immediate refreshing for
processes peculiar to the CPU Bus Unit,
such as for data links and DeviceNet remote
I/O communications, and for allocated CIO
Area/DM Area words when instructions are
executed, means greater refresh
responsiveness for CPU Bus Units.
Reduced Variation in Cycle Time During Data Processing
Instructions that require long execution time,
such as table data processing instructions
and text string processing instructions, are
Faster Instruction Execution and Faster Overall Performance
In addition to further improvements to the
instruction execution engine, which is the
core of overall PLC performance, the
high-speed RISC chip has been upgraded to
realize the fastest instruction execution
Common Processing
PCMIX Value
Cycle Time (
LD Instruction Processing Speed
OUT Instruction Processing Speed
Subroutine Processing Speed
Table data/
text string
processing
Cycle time for 128 inputs
and 128 outputs
Long
execution
time
The cycle is
temporarily extended
when the instruction
is executed.
Variation
)
0.3 ms
16
Basic instructions only: 38 Ksteps/ms
Including special instructions: 22 Ksteps/ms
20 ns
20 ns
2.1 µs
processed over multiple cycles to minimize
variations in cycle time and maintain stable
I/O response.
performance in the industry. Also, the new
models have a mode where instruction
execution and peripheral processing are
processed in parallel, enabling balanced
improvements in overall speed.
● CIO Area words
● DM Area words
● Specific Area for
Table data/
text string
processing
allocated to CPU
Bus Units
allocated for CPU
Bus Units
CPU Bus Units
CPU Unit
Background processing performed over
several cycles to limit the impact on cycle
time and thus reduce variation in cycle time.
DLNK
Unit name
Controller Link Unit
DeviceNet Unit
Serial Communications
Unit
Ethernet Unit
n
Only start of
processing
designated.
Immediate
I/O refresh
Refresh function
Data links
Remote I/O
Protocol macros
Socket service based
on manipulation of
specific bits.
Data exchange
during
communications
cycle
CPU Bus
Unit n
F-5

Related parts for C200HW-PD025