C200HW-PD025 Omron, C200HW-PD025 Datasheet - Page 16

no-image

C200HW-PD025

Manufacturer Part Number
C200HW-PD025
Description
Power Supply
Manufacturer
Omron
Datasheet

Specifications of C200HW-PD025

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
■ CS1 CPU Rack
A CS1 CPU Rack consists of a CPU Unit, Power Supply Unit, and Configuration Units (Basic I/O Units, Special I/O Units, and CPU Bus
Units).
● Required Units
● Types of Units
In the SYSMAC CS Series, Units are classified into the following three types. The number of Racks differs depending on the type.
4
CPU Rack
Basic I/O Units
Special I/O Units
CPU Bus Units
Rack
Type
Programmable Controllers SYSMAC
CS1 CPU Backplane (CS1W-BC@@@)
Power Supply Unit
CPU Unit
Maximum Number of Configuration Units
CS1 Basic I/O Units
CS1 Special I/O Units
CS1 CPU Backplane
CS1W-BC@@@ (See note.)
Appearance (example)
CS1 CPU Bus Units
Unit name
C200H Group-2 High-density
I/O Units
C200H Special I/O Units
C200H Basic I/O Units
Basic I/O Units
Special I/O Units
CPU Bus Units
Note: C200H Units cannot be used on the CPU Rack or Expansion Racks
if a CS-series-only CPU Backplane (CS1W-BC@@3) is used.
CS1G/H
Units with contact inputs and contact
outputs.
Special I/O Units provide more
advanced functions than do Basic I/O
Units, including I/O other than contact
inputs and contact outputs.
Examples of Special I/O Units are
Analog I/O Units and High-speed
Counter Units. They differ from CPU
Bus Units (including Network
Communications Units) in having a
smaller area for exchanging data with
the CPU Unit.
CPU Bus Units exchange data with
the CPU Unit via the CPU Bus.
Examples of CPU Bus Units are
Network Communications Units and
Serial Communications Units.
They differ from Special I/O Units in
having a larger area for exchanging
data with the CPU Unit.
1
1
1
Varies by backplane model
CS1 CPU Unit
CS1G/H-CPU@@H
Description
SYSMAC
CS1D-CPU67S
PROGRAMMABLE CONTROLLER
PERIPHERAL
OPEN
MCPWR
PORT
ERR/ALM
PRPHL
Required number of units
RUN
INH
BUSY
BKUP
COMM
Unit recognition method
In the CS1 System, CS1
Basic I/O Units, C200H
Basic I/O Units, and
Group-2 High-density I/O
Units are identified by
their mounting positions
(Rack and slot).
Recognized by the CPU
Unit according to the unit
number (CS-series
Special I/O Units: 0 to 95,
C200J Special I/O Units:
0 to 9, or 0 to 15) set with
the rotary switches on the
front panel.
Recognized by the CPU
Unit according to the unit
number (0 to F) set with
the rotary switch on the
front panel.
Power Supply Unit
C200HW-P@@@@(@)
CPU Rack
The Units mounted must
not exceed the maximum
I/O capacity of the CPU
Unit.
CS-series Special I/O
Units: 96 Units max.;
C200H Special I/O Units:
10 or 16 Units max. (From
1 to 4 unit numbers are
assigned per Unit,
depending on the model
of the Unit.)
A maximum of 16 Units
can be mounted.
No. of Units

Related parts for C200HW-PD025